Current controller for a bidirectional boost input stage equipped with an LCL (inductance-capacitance-inductance) filter

被引:6
作者
Fantino, Roberto [1 ]
Busada, Claudio [1 ]
Solsona, Jorge [1 ]
机构
[1] Univ Nacl Sur, IIIE Alfredo Desages, Dept Ingn Elect & Computadoras, CONICET, RA-8000 Bahia Blanca, Buenos Aires, Argentina
关键词
LCL (inductance-capacitance-inductance) filter; Active damping; Current control; 3-PHASE ACTIVE RECTIFIER; VOLTAGE-SOURCE CONVERTER; DESIGN; INVERTER; PERFORMANCE; SYSTEM; IMPLEMENTATION; MODULATION; RESONANCE; OUTPUT;
D O I
10.1016/j.energy.2015.02.045
中图分类号
O414.1 [热力学];
学科分类号
摘要
A control strategy for a low resonance frequency LCL (inductance-capacitance-inductance) filter used in the input stage of dc-dc bidirectional boost converters is proposed. When compared with the classical L filter, an LCL filter allows to obtain a cheaper topology. However, with an LCL topology, damping is needed for guaranteeing the system stability. In this paper an active damping strategy is designed. The needed damping is achieved via a dynamic controller. The controller consists of a simple PI (proportional-integral) controller plus a linear filter added in series with the PI integrator term. The modified PI controller achieves the active damping of the LCL filter and allows to arbitrarily place the system closed-loop poles. The proposed strategy only requires measurement of the variable to be controlled, the source current. Simulation and experimental results validate the proposed controller and show its effectiveness. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 40 条
[1]   Analysis and design of split-capacitor resistive-inductive passive damping for LCL filters in grid-connected inverters [J].
Balasubramanian, Arun Karuppaswamy ;
John, Vinod .
IET POWER ELECTRONICS, 2013, 6 (09) :1822-1832
[2]   Simplified Feedback Linearization Control of Three-Phase Photovoltaic Inverter With an LCL Filter [J].
Bao, Xianwen ;
Zhuo, Fang ;
Tian, Yuan ;
Tan, Peixuan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2739-2752
[3]   Software method for harmonic content evaluation of grid connected converters from distributed power generation systems [J].
Barote, L. ;
Marinescu, C. .
ENERGY, 2014, 66 :401-412
[4]   Modeling the effect of voltage ripple on the power output of photovoltaic modules [J].
Benavides, Nicholas D. ;
Chapman, Patrick L. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (07) :2638-2643
[5]   Active Damping for Three-Phase PWM Rectifiers With High-Order Line-Side Filters [J].
Bierhoff, Michael H. ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :371-379
[6]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[7]   A new mathematical model and control of a three-phase AC-DC voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :116-123
[8]  
Caro SD, 2005, POW EL APPL 2005 EUR, P10
[9]  
Choi S, 2013, POWER ELECT IET, V4, P168
[10]   Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633