High-Temperature (>500°C) Wall Thickness Monitoring Using Dry-Coupled Ultrasonic Waveguide Transducers

被引:126
作者
Cegla, Frederic B. [1 ]
Cawley, Peter [1 ]
Allin, Jonathan [2 ]
Davies, Jacob [2 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, London, England
[2] Permasense Ltd, Horsham, W Sussex, England
基金
英国工程与自然科学研究理事会;
关键词
PROPAGATION; SENSORS;
D O I
10.1109/TUFFC.2011.1782
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional ultrasonic transducers cannot withstand high temperatures for two main reasons: the piezoelectric elements within them depolarize, and differential thermal expansion of the different materials within a transducer causes them to fail. In this paper, the design of a high-temperature ultrasonic thickness gauge that bypasses these problems is described. The system uses a waveguide to isolate the vulnerable transducer and piezoelectric elements from the high-temperature measurement zone. Use of thin and long waveguides of rectangular cross section allows large temperature gradients to be sustained over short distances without the need for additional cooling equipment. The main problems that had to be addressed were the transmission and reception of ultrasonic waves into and from the testpiece that the waveguides are coupled to, and optimization of the wave propagation along the waveguide itself. It was found that anti-plane shear loading performs best at transmitting and receiving from the surface of a component that is to be inspected. Therefore, a non-dispersive guided wave mode in large-aspect-ratio rectangular strips was employed to transmit the anti-plane shear loading from the transducer to the measurement zone. Different joining methods to attach the waveguides to the component were investigated and experiments showed that clamping the waveguides to the component surface gave the best results. The thickness of different plate samples was consistently measured to within less than 0.1 mm. Performance at high temperatures was tested in a furnace at 730 degrees C for 4 weeks without signal degradation. Thicknesses in the range of 3 to 25 mm could be monitored using Hanning windowed tonebursts with 2 MHz center frequency.
引用
收藏
页码:156 / 167
页数:12
相关论文
共 39 条
  • [1] ACHENBACH J.D., 1975, Wave Propagation in Elastic Solids, North-Holland Series in Applied Mathematics and Mechanics, P165
  • [2] [Anonymous], 1999, Heat transfer
  • [3] ARAKI H, 1977, Patent No. 4014211
  • [4] Ashby MF., 1996, Engineering Materials, V1
  • [5] BOBBIN JE, 1979, MATER EVAL, V37, P28
  • [6] Cegla F., 2006, THESIS IMPERIAL COLL
  • [7] Energy concentration at the center of large aspect ratio rectangular waveguides at high frequencies
    Cegla, F. B.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (06) : 4218 - 4226
  • [8] Chang FK, 1999, STRUCTURAL HEALTH MONTORING 2000, pXIX
  • [9] Dixon S, 1995, INSIGHT, V37, P368
  • [10] *FERR A S, 2010, FULL DAT MATR