Measuring Degree of Contamination by Semi-volatile Organic Compounds (SVOC) in Interiors of Korean Homes and Kindergartens

被引:2
作者
Kim, Hyun-tae [1 ]
Tanabe, Shin-ichi [2 ]
机构
[1] Yamaguchi Univ, Architectural & Design Sect, Yamaguchi, Japan
[2] Waseda Univ, Dept Architecture, Tokyo, Japan
基金
日本学术振兴会;
关键词
plasticizer; house dust; SVOC; PVC sheet; INDOOR AIR-QUALITY; IN-HOUSE DUST; HONG-KONG; PHTHALATE-ESTERS; FLAME RETARDANTS; EXPOSURE; CHILDREN; MICROENVIRONMENTS; ASSOCIATION; FORMALDEHYDE;
D O I
10.3130/jaabe.16.661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PVC floor material is widely used in Korean homes, and people customarily sit or lie on the floor surface. This could potentially put residents of such homes at high risk of exposure to semi-volatile organic compounds (SVOCs). However, there is a current lack of information regarding the degree of SVOC contamination in Korean homes. Therefore, this study was implemented to measure SVOC concentration in the air and house dust in homes and kindergartens, places where children spend long periods of time. The substances analyzed were 2E1H, D6, DEP, TBP, TCEP, DBP, TPP, DOA, and DEHP. Amounts of 2E1H, D6, DEP, DBP, and DEHP were detected in the air of the homes included in the study, and the average air concentrations of DBP and DEHP were 0.53 mu g/m(3) and 0.28 mu g/m(3), respectively. The average dust DEHP concentrations in the rooms of homes and kindergartens were 2,800 mu g/g and 4,350 mu g/g, respectively, showing that higher values were measured in kindergartens. The measured DEHP concentrations in the dust of both homes and kindergartens where PVC floor materials are used were high.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 54 条
  • [31] PVC - as flooring material - and its association with incident asthma in a Swedish child cohort study
    Larsson, M.
    Hagerhed-Engman, L.
    Kolarik, B.
    James, P.
    Lundin, F.
    Janson, S.
    Sundell, J.
    Bornehag, C. G.
    [J]. INDOOR AIR, 2010, 20 (06) : 494 - 501
  • [32] Investigation of indoor air quality at residential homes in Hong Kong - case study
    Lee, SC
    Li, WM
    Ao, CH
    [J]. ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 225 - 237
  • [33] FORMALDEHYDE IN CONVENTIONAL HOMES IN TAIWAN
    LIN, JM
    YAO, YH
    [J]. ENVIRONMENT INTERNATIONAL, 1993, 19 (06) : 561 - 568
  • [34] Dust: A metric for use in residential and building exposure assessment and source characterization
    Lioy, PJ
    Freeman, NCG
    Millette, JR
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 (10) : 969 - 983
  • [35] Indoor residential chemical emissions as risk factors for-respiratory and allergic effects in children: a review
    Mendell, M. J.
    [J]. INDOOR AIR, 2007, 17 (04) : 259 - 277
  • [36] Mendell M.J., 1993, Indoor AirZ, P227
  • [37] Total volatile organic compounds (TVOC) in indoor air quality investigations
    Molhave, L
    Clausen, G
    Berglund, B
    de Ceaurriz, J
    Kettrup, A
    Lindvall, T
    Maroni, M
    Pickering, AC
    Risse, U
    Rothweiler, H
    Seifert, B
    Younes, M
    [J]. INDOOR AIR, 1997, 7 (04) : 225 - 240
  • [38] Molhave L., 1991, INDOOR AIR, V4, P357, DOI [10.1111/j.1600-0668.1991.00001.x, DOI 10.1111/J.1600-0668.1991.00001.X]
  • [39] Do indoor chemicals promote development of airway allergy?
    Nielsen, G. D.
    Larsen, S. T.
    Olsen, O.
    Lovik, M.
    Poulsen, L. K.
    Glue, C.
    Wolkoff, P.
    [J]. INDOOR AIR, 2007, 17 (03) : 236 - 255
  • [40] Exposure to the mixtures of organic compounds in homes in Japan
    Park, JS
    Ikeda, K