Diagnostic Performance of the Simultaneous Acquisition Rest 99mTc-Tetrofosmin/Stress 201Tl Dual-Isotope Protocol With a Semiconductor Camera - Comparison With the Rest-Stress 99mTc-Tetrofosmin Protocol -

被引:3
|
作者
Kawamura, Itta [1 ]
Kajiura, Ryo [1 ]
Motoji, Yusuke [1 ]
Okamoto, Syuichi [1 ]
Tanigaki, Toru [1 ]
Omori, Hiroyuki [1 ]
Hirata, Tetsuo [1 ]
Kikuchi, Jun [1 ]
Ota, Hideaki [1 ]
Sobue, Yoshihiro [1 ]
Miyake, Taiji [1 ]
Tsunekawa, Tomohiro [1 ]
Kato, Takayoshi [1 ]
Kawase, Yoshiaki [1 ]
Okubo, Munenori [1 ]
Kamiya, Hiroki [1 ]
Tsuchiya, Kunihiko [1 ]
Tomita, Shinji [1 ]
Hirakawa, Akihiro [2 ]
Kondo, Takeshi [1 ]
Suzuki, Takahiko [1 ]
Matsuo, Hitoshi [1 ]
机构
[1] Gifu Heart Ctr, Gifu, Japan
[2] Univ Tokyo, Dept Biostat & Bioinformat, Grad Sch Med, Tokyo, Japan
关键词
Cadmium-zinc-telluride; Myocardial perfusion imaging; Simultaneous dual isotope; EMISSION COMPUTED-TOMOGRAPHY; MYOCARDIAL-PERFUSION SPECT; CORONARY-ARTERY-DISEASE; HIGH-SPEED; SEPARATE ACQUISITION; PROGNOSTIC VALUE; GAMMA-CAMERA; TC-99M; EXERCISE; PREDICTION;
D O I
10.1253/circj.CJ-18-0363
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress Tc-99m-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest Tc-99m-tetrofosmin/stress Tl-201 dual-isotope protocol (SDI protocol) with a semiconductor camera. Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. Conclusions: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
引用
收藏
页码:2837 / 2844
页数:8
相关论文
共 24 条
  • [1] Incremental prognostic value of myocardial SPET with dual-isotope rest 201Tl/stress 99mTc-tetrofosmin
    Groutars, RGEJ
    Verzijlbergen, JF
    Zwinderman, AH
    Tiel-van Buul, MMC
    Ascoop, CAPL
    van Hemel, NM
    van der Wall, EE
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) : 46 - 52
  • [2] Clinical Feasibility of Simultaneous Acquisition Rest 99mTc/Stress 201Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera
    Makita, Ayano
    Matsumoto, Naoya
    Suzuki, Yasuyuki
    Hori, Yusuke
    Kuronuma, Keiichiro
    Yoda, Shunichi
    Kasama, Shu
    Iguchi, Nobuo
    Suzuki, Yasuhiro
    Hirayama, Atsushi
    CIRCULATION JOURNAL, 2016, 80 (03) : 689 - 695
  • [3] Feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin single photon emission computed tomography for quantification of myocardial perfusion reserve in patients with stable coronary artery disease
    Han, Sangwon
    Kim, Young-Hak
    Ahn, Jung-Min
    Kang, Soo-Jin
    Oh, Jungsu S.
    Shin, Eonwoo
    Sung, Changhwan
    Chae, Sun Young
    Park, Seung-Jung
    Grimberg, Gillan
    Kovalski, Gil
    Moon, Dae Hyuk
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (12) : 2173 - 2180
  • [4] Clinical Utility of a Slow 201Tl Washout Rate in the Detection of Multi-Vessel Coronary Artery Disease Using a Simultaneous Acquisition Rest 99 mTc/Stress 201Tl Protocol and a Semiconducting Gamma Camera
    Sugai, Shonosuke
    Matsumoto, Naoya
    Makita, Ayano
    Kuronuma, Keiichiro
    Suzuki, Yasuyuki
    Yoda, Shunichi
    Okumura, Yasuo
    Amano, Yasuo
    CIRCULATION JOURNAL, 2022, 86 (09) : 1409 - 1415
  • [5] Feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin single photon emission computed tomography for quantification of myocardial perfusion reserve in patients with stable coronary artery disease
    Sangwon Han
    Young-Hak Kim
    Jung-Min Ahn
    Soo-Jin Kang
    Jungsu S. Oh
    Eonwoo Shin
    Changhwan Sung
    Sun Young Chae
    Seung-Jung Park
    Gillan Grimberg
    Gil Kovalski
    Dae Hyuk Moon
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 2173 - 2180
  • [6] Low-dose single acquisition rest 99mTc/stress 201Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation
    Dey, Thomas
    Backus, Barbra E.
    Romijn, R. Leo
    Wieczorek, Herfried
    Verzijlbergen, J. Fred
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (03) : 536 - 547
  • [7] Low-dose single acquisition rest 99mTc/stress 201Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation
    Thomas Dey
    Barbra E. Backus
    R. Leo Romijn
    Herfried Wieczorek
    J. Fred Verzijlbergen
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 536 - 547
  • [8] Quantitative Analysis of Iodine Image of Dual-energy Computed Tomography at Rest Comparison With 99mTc-Tetrofosmin Stress-rest Single-photon Emission Computed Tomography Myocardial Perfusion Imaging as the Reference Standard
    Nakahara, Takehiro
    Toyama, Takuji
    Jinzaki, Masahiro
    Seki, Ryotaro
    Saito, Yuichiro
    Higuchi, Tetsuya
    Yamada, Minoru
    Arai, Masashi
    Tsushima, Yoshito
    Kuribayashi, Sachio
    Kurabayashi, Masahiko
    JOURNAL OF THORACIC IMAGING, 2018, 33 (02) : 97 - 104
  • [9] Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result
    Giorgetti, Assuero
    Kusch, Annette
    Casagranda, Mirta
    Tagliavia, Irene D'Aragona
    Marzullo, Paolo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (02) : 276 - 285
  • [10] COMBINED REST TL-201 STRESS TECHNETIUM-99M-TETROFOSMIN SPECT - FEASIBILITY AND DIAGNOSTIC-ACCURACY OF A 90-MINUTE PROTOCOL
    MAHMOOD, S
    GUNNING, M
    BOMANJI, JB
    GUPTA, NK
    COSTA, DC
    JARRITT, PH
    SWANTON, H
    ELL, PJ
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (06) : 932 - 935