Air conditioning in the region of Madrid, Spain: An approach to electricity consumption, economics and CO2 emissions

被引:54
作者
Izquierdo, M. [1 ,2 ]
Moreno-Rodriguez, A. [1 ]
Gonzalez-Gil, A. [2 ]
Garcia-Hernando, N. [1 ]
机构
[1] Univ Carlos III Madrid, Escuela Politecn Super, Madrid 28911, Spain
[2] CSIC, Inst Ciencias Construcc Eduardo Torroja, Madrid 28033, Spain
关键词
Air conditioning; Electricity consumption; Part load; Cooling cost; CO2; emissions;
D O I
10.1016/j.energy.2010.12.068
中图分类号
O414.1 [热力学];
学科分类号
摘要
An understanding of electricity consumption due to residential air conditioning (AC) may improve production and environmental impact strategy design. This article reports on a study of peak and seasonal electricity consumption for residential air conditioning in the region of Madrid, Spain. Consumption was assessed by simulating the operation of AC units at the outdoor summer temperature characteristics of central Spain. AC unit performance when operating under part load conditions in keeping with weather conditions was also studied to find cooling demand and energy efficiency. Likewise final electricity consumption was computed and used to calculate energy costs and greenhouse gas emissions (GHGs). Cooling demand, when family holidays outside the region were factored into the calculations, came to 1.46 x 10(9) kWh. Associated seasonal electricity demand was 617 x 10(6) kWh and seasonal performance of AC units around 2.4. Electricity consumption in the whole region was observed to peak on 30 June 2008 at 5.44 x 10(6) kW, being the load attributable to residential AC 1.79 x 10(6) kW, resulting about 33% of the total peak consumption. The seasonal cost per household was about (sic)156 and the total equivalent warming impact was 572 x 10(3) t CO2. The method proposed can be adapted for use in other regions. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1630 / 1639
页数:10
相关论文
共 21 条
[1]  
[Anonymous], 2006, SOLVAY FLUOR SOLKANE
[2]  
[Anonymous], 2009, ASHRAE Handbook|Fundamentals
[3]   Experimental analysis of the scroll compressor performances varying its speed [J].
Aprea, C ;
Mastrullo, R ;
Renno, C .
APPLIED THERMAL ENGINEERING, 2006, 26 (10) :983-992
[4]  
BERNIER J, 1979, POMPE CHALEUR MODE E
[5]  
CHEN Y, 2002, INT J REFRIG, P751
[6]  
*COM MADR, 2005, PLAN EN COM MADR 200
[7]  
*DANF, 2008, MTZ0505 DANF
[8]  
*INT I REFR, 2009, BRIEFS JAP REFR LEAK, P39
[9]   Air conditioning using an air-cooled single effect lithium bromide absorption chiller:: Results of a trial conducted in Madrid in August 2005 [J].
Izquierdo, M. ;
Lizarte, R. ;
Marcos, J. D. ;
Gutierrez, G. .
APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) :1074-1081
[10]  
*MARM, 2010, INV GAS EF INV ESP