Evaluation of Passive Diffusive-Adsorptive Samplers for Use in Assessing Time-Varying Indoor Air Impacts Resulting from Vapor Intrusion

被引:1
作者
Guo, Yuanming [1 ,2 ]
O'Neill, Harry [3 ]
Dahlen, Paul [2 ]
Johnson, Paul C. [4 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Environm & Biol Engn, Nanjing 210094, Peoples R China
[2] Arizona State Univ, Sch Sustainable Engn & Built Environm, Tempe, AZ 85287 USA
[3] Beacon Environm, Forest Hill, MD 21050 USA
[4] Colorado Sch Mines, Dept Civil & Environm Engn, Golden, CO 80401 USA
关键词
SOIL; VOCS; VARIABILITY; MODEL;
D O I
10.1111/gwmr.12481
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Passive diffusive-adsorptive samplers are being considered for vapor intrusion (VI) pathway assessment, particularly where multi-week time-weighted average concentrations are desired. Recent studies have shown that passive samplers can produce accurate results under well-controlled steady concentration conditions, and field performance was also demonstrated at several sites. The objective of this study was to examine passive sampler performance in settings with time-varying indoor air concentrations, through a comparison of passive sampler results to concentrations determined by 24-h active sorbent tube sampling in a series of multi-week deployments. Sampling was performed in a well-instrumented residential building as well as industrial buildings, over periods of time ranging from 1 to 7 weeks. Strong linear correlations were noted between passive and active sampling concentration results for some passive samplers, with passive sampling results being similar to or lower than measured active sampling results by about 50% for those samplers in the residential study and about 25% higher in the industrial building study. Other samplers produced poor agreement. The conclusion from this study is that some passive samplers have great potential for use in multi-week indoor air quality monitoring. It was further determined that there is need for accepted procedures to validate and calibrate passive samplers for use in the field.
引用
收藏
页码:38 / 49
页数:12
相关论文
共 37 条
[1]  
ASTM, 2009, D4597 ASTM
[2]  
ASTM, 2018, D624608 ASTM
[3]  
ASTM, 2003, D630698 ASTM
[4]  
CEN, 2004, IND AIR QUAL DIFF SA
[5]  
CH2MHill, 2010, TRAV AIR FORC BAS EN
[6]   Field evaluation of thermal and chemical desorption BTEX radial diffusive sampler radiello® compared with active (pumped) samplers for ambient air measurements [J].
Cocheo, Claudio ;
Boaretto, Caterina ;
Pagani, Diego ;
Quaglio, Franco ;
Sacco, Paolo ;
Zaratin, Laura ;
Cottica, Danilo .
JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (02) :297-306
[7]  
CWQCB/DTSC, 2020, SUPPL GUID SCREEN EV
[8]   Observed Spatial and Temporal Distributions of CVOCs at Colorado and New York Vapor Intrusion Sites [J].
Folkes, David ;
Wertz, William ;
Kurtz, Jeffrey ;
Kuehster, Theodore .
GROUND WATER MONITORING AND REMEDIATION, 2009, 29 (01) :70-80
[9]  
Grisr A., 2017, LTD REFERENCE PARTIA
[10]   Development and Validation of a Controlled Pressure Method Test Protocol for Vapor Intrusion Pathway Assessment [J].
Guo, Yuanming ;
Dahlen, Paul ;
Johnson, Paul C. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (12) :7117-7125