Quantitative Dual-Energy Imaging in the Presence of Metal Implants Using Locally Constrained Model-Based Decomposition

被引:2
作者
Liu, Stephen Z. [1 ]
Siewerdsen, Jeffrey H. [1 ]
Stayman, J. Webster [1 ]
Zbijewski, Wojciech [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
关键词
constrained optimization; primal-dual algorithm; model-based reconstruction; cone-beam CT; quantitative imaging; dual-energy imaging; material decomposition; metal artifacts; CONE-BEAM CT;
D O I
10.1117/12.2582277
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To mitigate effects of metal artifacts in Dual-Energy (DE) CT imaging, we introduce a constrained optimization algorithm to enable simultaneous reconstruction-decomposition of three materials: two tissues-of-interest and the metal. Methods: The volume conservation principle and nonnegativity of volume fractions were incorporated as a pair of linear constraints into the Model-Based Material Decomposition (MBMD) algorithm. This enabled solving for three unknown material concentrations from DE projection data. A primal-dual Ordered Subsets Predictor-Corrector Interior-Point (OS-PCIP) algorithm was derived to perform the optimization in the proposed constrained-MBMD (CMBMD). To improve computational efficiency and monotonicity of CMBMD, we investigated an approach where the constraint was applied locally onto a small region containing the metal (identified from a preliminary reconstruction) during initial iterations, followed by final iterations with the constraint applied globally. Validation studies involved simulations and test bench experiments to assess the quantitative accuracy of bone concentration measurements in the presence of fracture fixation hardware. In all studies, DE data was acquired using a kVp-switching protocol with the 60 kVp low-energy beam and the 140 kVp high-energy beam. The system geometry emulated the extremity Cone-Beam CT (CBCT). Simulation studies included: i) a cylindrical phantom (80 mm diameter) with a 30 mm long Ti screw and an insert of varying cortical bone concentrations (3 - 13%), and ii) a realistic tibia phantom created from patient CBCT data with Ti fixation hardware of increasing complexity. The test bench experiment involved a 100 mm diameter water bath containing four Ca inserts (6.5 - 39.1% bone concentration) and a Ti plate. Results: CMBMD substantially reduced artifacts in DE decompositions in the presence of metal. The sequentially local-global constraint strategy resulted in more monotonic convergence than using a global constraint for all iterations. In the simulation studies, CMBMD achieved quantitative accuracy within similar to 12% of nominal bone concentration in areas adjacent to metal, and within similar to 5% in areas further away from the metal, compared to similar to 80% error for the two -material MBMD. In the test bench study, CMBMD generated similar to 40% reduction in the error of bone concentration estimates compared to MBMD for nominal insert concentrations of <250 mg/mL, and similar to 12% reduction for concentrations >250 mg/mL. Conclusion: Proposed CMBMD enables accurate DE decomposition in the presence of metal implants by incorporating the metal as an additional base material. Proposed method will be particularly useful in quantitative orthopedic imaging, which is often challenged by metal fracture fixation and joint replacement hardware.
引用
收藏
页数:8
相关论文
共 17 条
[1]   Interior-point methods for nonconvex nonlinear programming: Filter methods and merit functions [J].
Benson, HY ;
Vanderbei, RJ ;
Shanno, DF .
COMPUTATIONAL OPTIMIZATION AND APPLICATIONS, 2002, 23 (02) :257-272
[2]  
Cao Q, 2019, MED PHYS, V46, pE399
[3]   Biological effects of MRI contrast agents: gadolinium retention, potential mechanisms and a role for phosphorus [J].
Garcia, Joel ;
Liu, Stephen Z. ;
Louie, Angelique Y. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2017, 375 (2107)
[4]   Known-Component Model-Based Material Decomposition for Dual Energy Imaging of Bone Compositions in the Presence of Metal Implant [J].
Liu, S. Z. ;
Tilley, S. ;
Cao, Q. ;
Siewerdsen, J. H. ;
Stayman, J. W. ;
Zbijewski, W. .
15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
[5]  
Liu S. Z., 2020, 6 INT C IM FORM XRAY 6 INT C IM FORM XRAY
[6]  
Liu S. Z., 2020, MEDICAL IMAGING 2020, V11317
[7]   Model-based dual-energy tomographic image reconstruction of objects containing known metal components [J].
Liu, Stephen Z. ;
Cao, Qian ;
Tivnan, Matthew ;
Tilley, Steven, II ;
Siewerdsen, Jeffrey H. ;
Stayman, J. Webster ;
Zbijewski, Wojciech .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24)
[8]   Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CT [J].
Long, Yong ;
Fessler, Jeffrey A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) :1614-1626
[9]   ADAPTIVE BARRIER UPDATE STRATEGIES FOR NONLINEAR INTERIOR METHODS [J].
Nocedal, Jorge ;
Wachter, Andreas ;
Waltz, Richard A. .
SIAM JOURNAL ON OPTIMIZATION, 2009, 19 (04) :1674-1693
[10]   A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data [J].
Schmidt, Taly Gilat ;
Barber, Rina Foygel ;
Sidky, Emil Y. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) :1808-1819