摘要
Background Patients with systemic sclerosis (SSc) frequently suffer from recalcitrant digital ulceration because of impaired cutaneous blood flow (CBF). A simple and accurate CBF measurement would be helpful to evaluate the disease status and efficacy of treatment in such patients. Objectives To examine the feasibility of a newly developed, micromachined integrated laser blood flowmeter (MILBF) for evaluation of abnormal CBF responses in patients with SSc. Methods CBF of finger pulp was measured in eight patients with SSc and in six healthy controls using MILBF. CBF in the steady state and the responses to the arm-raising test and cold provocation were assessed. The therapeutic efficacy of a single and an intensive prostaglandin E-1 (PGE(1)) infusion treatment was also evaluated in some of the SSc patients. Results The patients with SSc showed significantly lower steady-state CBF than controls. The rate of blood flow with cold provocation and the velocity of blood flow recovery after cold provocation (VR-CP) tended to be lower in patients with SSc. Augmentation of amplitude of the digital pulse wave by arm raising (AA-AR) was observed in controls, but not in patients with SSc. We also found that VR-CP and AA-AR may be good markers for evaluating the efficacy of vasodilatory treatment. It should be noted that the examined patients did not complain of any pain and/or distress during the arm-raising test, as opposed to during cold provocation. Conclusions CBF assessment using MILBF and an arm-raising test is accurate, noninvasive and well tolerated and thus the combination may be a better alternative method to evaluate abnormal CBF and efficacy of treatment in patients with SSc.
引用
收藏
页码:690 / 697
页数:8
相关论文
共 2 条
  • [1] Use of a simple arm-raising test with a portable laser Doppler blood flow meter to detect dehydration
    Nogami, H.
    Iwasaki, W.
    Abe, T.
    Kimura, Y.
    Onoe, A.
    Higurashi, E.
    Takeuchi, S.
    Kido, M.
    Furue, M.
    Sawada, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H4) : 411 - 419
  • [2] Useful method to monitor the physiological effects of alcohol ingestion by combination of micro-integrated laser Doppler blood flow meter and arm-raising test
    Iwasaki, Wataru
    Nogami, Hirofumi
    Ito, Hiroki
    Gotanda, Takeshi
    Peng, Yao
    Takeuchi, Satoshi
    Furue, Masutaka
    Higurashi, Eiji
    Sawada, Renshi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H10) : 759 - 765