An ELIME assay for hepatitis A virus detection

被引:6
|
作者
Micheli, Laura [1 ,2 ]
Fasoli, Andrea [1 ]
Attar, Aisha [3 ,6 ]
Donia, Domenica T. [4 ]
Divizia, Maurizio [4 ]
Amine, Aziz [3 ]
Palleschi, Giuseppe [1 ,2 ]
Salazar Carballo, Pedro A. [5 ]
Moscone, Danila [1 ,2 ]
机构
[1] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci, I-00133 Rome, Italy
[2] Consorzio Interuniv Biostrutture & Biosistemi INB, Viale Medaglie dOro 305, I-00136 Rome, Italy
[3] Hassan II Univ Casablanca, Fac Sci & Tech, BP 146, Mohammadia 20650, Morocco
[4] Univ Roma Tor Vergata, Dept Expt Med & Surg, Via Montpellier 1, I-00133 Rome, Italy
[5] Univ La Laguna, Fac Med Sci, Lab Sensors Biosensors & Mat, Neurochem & Neuroimaging Grp, Campus Ofra S-N, Tenerife 38071, Spain
[6] Univ Illinois, Coll Med, Dept Pharmacol, 835 S Wolcott Ave E403 MC868, Chicago, IL 60612 USA
关键词
Hepatitis A virus; ELIME; Screen printed electrodes; Polydopamine-modified magnetic nanobeads; Food; SOLID-PHASE EXTRACTION; MAGNETIC NANOPARTICLES; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOMAGNETIC SEPARATION; WATER SAMPLES; UNITED-STATES; BIOSENSOR; NOROVIRUS; PCR; OUTBREAK;
D O I
10.1016/j.talanta.2021.122672
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
C An Enzyme Linked ImmunoMagnetic Electrochemical assay (ELIME) was developed for the detection of the hepatitis A virus (HAV). This system is based on the use of new polydopamine-modified magnetic nanobeads as solid support for the immunochemical chain, and an array of 8 screen-printed electrodes as a sensing platform. Enzymatic-by-product is quickly measured by differential pulse voltammetry. For this purpose, all analytical parameters were optimized; in particular, different blocking reagents were evaluated in order to minimize the nonspecific interaction of bioreagents. Using the ELIME assays, a quantitative determination of HAV can be achieved with a detection limit of 1.10(- 11) IU mL(-1) and a working range between 10(-10) - 5 x 10(-7) IU mL(-1). The cross-reactivity of the commercial monoclonal antibodies against HAV used in ELIME assays was tested for Coxsackie B4, resulting very low. The sensitivity was also investigated and compared with spectrophotometric sandwich ELISA. The average relative standard deviation (RSD) of the ELIME method was less than 5% for the assays performed on the same day, and 7% for the measurements made on different days. The proposed system was applied to the cell culture of HAV, which title was quantified by Real-Time Quantitative Reverse Transcription PCR (RT-qPCR). To compare the results, a correlation between the units used in ELIME (IU mL(-1)) and those used in RT-qPCR (genome mL(-1)) was established using a HAV-positive sample, resulting in 1 IU mL(- 1)-10(-4) gen mL(-1) (R-2 = 0.978). The ELIME tool exhibits good stability and high biological selectivity for HAV antigen detection and was successfully applied for the determination of HAV in tap water.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A new assay for quantitative detection of hepatitis A virus
    Persson, Sofia
    Alm, Erik
    Karlsson, Mans
    Enkirch, Theresa
    Norder, Helene
    Eriksson, Ronnie
    Simonsson, Magnus
    Ellstrom, Patrik
    JOURNAL OF VIROLOGICAL METHODS, 2021, 288
  • [2] Development of a sandwich ELIME assay exploiting different antibody combinations as sensing strategy for an early detection of Campylobacter
    Fabiani, L.
    Delibato, E.
    Volpe, G.
    Piermarini, S.
    De Medici, D.
    Palleschi, G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 : 318 - 325
  • [3] Evaluation of an Enzyme-Linked Magnetic Electrochemical Assay for Hepatitis a Virus Detection in Drinking and Vegetable Processing Water
    DAgostino, Cristine
    Cancelliere, Rocco
    Ceccarelli, Antonio
    Moscone, Danila
    Cozzi, Loredana
    La Rosa, Giuseppina
    Suffredini, Elisabetta
    Micheli, Laura
    CHEMOSENSORS, 2024, 12 (09)
  • [4] A Cell-Based Electrochemical Biosensor for the Detection of Infectious Hepatitis A Virus
    Kaur, Dilmeet
    Esseili, Malak A.
    Ramasamy, Ramaraja P.
    BIOSENSORS-BASEL, 2024, 14 (12):
  • [5] Optimization of Methods for Detecting Hepatitis A Virus in Food
    de Paula, V. S.
    Gaspar, A. M. C.
    Villar, L. M.
    FOOD AND ENVIRONMENTAL VIROLOGY, 2010, 2 (01) : 47 - 52
  • [6] The Advancement of Nanomaterials for the Detection of Hepatitis B Virus and Hepatitis C Virus
    Shi, Wanting
    Li, Kang
    Zhang, Yonghong
    MOLECULES, 2023, 28 (20):
  • [7] ELIME assay vs Real-Time PCR and conventional culture method for an effective detection of Salmonella in fresh leafy green vegetables
    Fabiani, L.
    Pucci, E.
    Delibato, E.
    Volpe, G.
    Piermarini, S.
    De Medici, D.
    Capuano, F.
    Palleschi, G.
    TALANTA, 2017, 166 : 321 - 327
  • [8] Comparison of concentration methods for detection of hepatitis A virus in water samples
    Qiao, Yuting
    Sui, Zhiwei
    Hu, Guoliang
    Cao, Huabin
    Yang, Guoxiang
    Li, Yong
    Lei, Yongsong
    Zhao, Lihua
    Chen, Quanjiao
    VIROLOGICA SINICA, 2016, 31 (04) : 331 - 338
  • [9] Molecular biological detection of food-borne viruses, in respect to noroviruses and hepatitis A virus in shellfish
    Schrader, C
    Reetz, J
    Süss, J
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2003, 116 (11-12): : 496 - 505
  • [10] Effect of Probe Design on Chemiluminescence Detection of Hepatitis B Virus and Hepatitis C Virus
    Ali, Zeeshan
    Tang, Yongjun
    Deng, Yan
    Li, Hanmei
    Wang, Zhifei
    Li, Zhiyang
    Dai, Jianguo
    Liu, Hongna
    Su, Enben
    Chen, Zhu
    Li, Song
    Chen, Hui
    Wang, Lijun
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2018, 10 (01) : 127 - 134