The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates

被引:94
作者
Benjamin, Richard J.
Wagner, Stephen J.
机构
[1] Amer Red Cross, Biomed Serv, Med Off, Washington, DC 20006 USA
[2] Amer Red Cross, Jerome H Holland Lab, Rockville, MD USA
关键词
D O I
10.1111/j.1537-2995.2007.01326.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Septic reactions continue to be reported with culture-tested platelet (PLT) products, probably due to false-negative results associated with inadequate sampling of low-concentration bacteria. The mechanism of test failure was modeled and false-negative rates were estimated utilizing published data. STUDY DESIGN AND METHODS: The effect of concentration on the probability of sampling one or more viable bacteria in an 8-mL sample of a 300-mL product was determined. The ratio of single-versus dual-bottle-positive tests in repeated cultures utilizing two-bottle systems was used to assess mean bacterial concentrations and to predict false-negative tests. RESULTS: Published reports reveal a mean residual risk of sepsis of 2.3 per 10(5) products tested. Modeling the effect of concentration predicts that 50 and 95 percent of samples are detected at 0.09 and 0.36 CFU per mL for organisms that grow under both aerobic and anaerobic conditions, and suggest a 50 and 5 percent false-negative culture rate at these concentrations. Reanalysis of published studies documenting single-bottle growth of nonfastidious organisms indicate that low bacterial concentrations are frequently encountered and predict false-negative cultures in products contaminated with common bacteria at rates that varied from 4 to more than 75 percent. The model highlights the weakness of the AABB definition of falsepositive culture results at low bacterial concentrations, especially for organisms that grow poorly in aerobic storage conditions. CONCLUSION: Continuing reports of septic reactions after transfusion of culture-tested apheresis PLTs, and frequent single-bottle-positive results when testing with two-bottle systems, suggest appreciable levels of false-negative results with a commercially available bacterial detection system (BacT/ALERT, bioMereiux) as implemented.
引用
收藏
页码:1381 / 1389
页数:9
相关论文
共 32 条
  • [1] Protecting the blood supply from emerging pathogens: The role of pathogen inactivation
    Allain, JP
    Bianco, C
    Blajchman, MA
    Brecher, ME
    Busch, M
    Leiby, D
    Lin, L
    Stramer, S
    [J]. TRANSFUSION MEDICINE REVIEWS, 2005, 19 (02) : 110 - 126
  • [2] *AM ASS BLOOD BANK, 2004, ACT FOLL IN POS TEST
  • [3] The reliability of bacterial detection in platelets
    AuBuchon, J. P.
    [J]. ISBT SCIENCE SERIES, VOL 1, NO 1: STATE OF THE ART PRESENTATIONS, 2006, 1 (01): : 59 - 63
  • [4] Improving the bacteriological safety of platelet transfusions
    Blajchman, MA
    Goldman, M
    Baeza, F
    [J]. TRANSFUSION MEDICINE REVIEWS, 2004, 18 (01) : 11 - 24
  • [5] Bacterial contamination of cellular blood components: risks, sources and control
    Blajchman, MA
    [J]. VOX SANGUINIS, 2004, 87 : 98 - 103
  • [6] Brecher M E, 2002, Dev Biol (Basel), V108, P69
  • [7] Brecher Mark E, 2004, Curr Hematol Rep, V3, P121
  • [8] Evaluation of BacT/ALERT plastic culture bottles for use in testing pooled whole blood-derived leukoreduced platelet-rich plasma platelets with a single contaminated unit
    Brecher, ME
    Hay, SN
    Rose, AD
    Rothenberg, SJ
    [J]. TRANSFUSION, 2005, 45 (09) : 1512 - 1517
  • [9] Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands
    de Korte, D
    Curvers, J
    de Kort, WLAM
    Hoekstra, T
    van der Poel, CL
    Beckers, EAM
    Marcelis, JH
    [J]. TRANSFUSION, 2006, 46 (03) : 476 - 485
  • [10] Diversion of first blood volume results in a reduction of bacterial contamination for whole-blood collections
    de Korte, D
    Marcelis, JH
    Verhoeven, AJ
    Soeterboek, AM
    [J]. VOX SANGUINIS, 2002, 83 (01) : 13 - 16