An evaluation of semiconductor and ionization chamber detectors for diagnostic x-ray dosimetry measurements

被引:14
作者
Martin, C. J. [1 ]
机构
[1] Gartnavel Royal Hosp, Dept Clin Phys & Bio Engn, Glasgow G12 0XH, Lanark, Scotland
关键词
D O I
10.1088/0031-9155/52/15/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosemeters for performance testing of x-ray equipment may utilize semiconductor technology or ionization chambers ( ICs). Semiconductor dosemeters incorporate several elements into the detectors from which compensation for variations in response with photon energy is derived. The design of the detectors influences their response with angle and this is different from that of ICs. The responses of semiconductor detectors ( SDs) and ICs to x-ray beams with a variety of radiation qualities have been measured in order to assess differences in response. Measurements have been made with experimental arrangements simulating use of the detectors in performance testing of digital radiography and fluoroscopy equipment. Results show that differences in photon energy responses between the detectors are small, but because ICs are sensitive to radiation incident from all angles, they record more scattered radiation than SDs. Implications of differences in detector responses are discussed and recommendations made about their use. SDs are more appropriate for measurements of image receptor doses and are recommended for setting up automatic exposure control devices for digital radiography. ICs are suitable for assessment of patient entrance surface dose rate measurements. Correction factors that could be applied to allow comparisons between measurements with different dosemeters are proposed.
引用
收藏
页码:4465 / 4480
页数:16
相关论文
共 11 条
[1]  
*BIR, 2001, ASS QUAL DIAGN IM DE
[2]   The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray [J].
Bower, MW ;
Hintenlang, DE .
HEALTH PHYSICS, 1998, 75 (02) :197-204
[3]   Calibrating automatic exposure control devices for digital radiography [J].
Doyle, P. ;
Martin, C. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21) :5475-5485
[4]   BACKSCATTER FACTORS FOR DIAGNOSTIC-RADIOLOGY (1-4 MM AL HVL) [J].
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (12) :1465-1474
[5]  
HEARD MJ, 1963, PERSONNEL DOSIMETRY, P89
[6]   TYPE TESTING OF THE SIEMENS PLESSEY ELECTRONIC PERSONAL DOSIMETER [J].
HIRNING, CR ;
YUEN, PS .
HEALTH PHYSICS, 1995, 69 (01) :46-66
[7]  
IPEM, 2005, 91 IPEM
[8]  
*IPEM, 1996, 32 IPEM
[9]   Protocol for measurement of patient entrance surface dose rates for fluoroscopic X-ray equipment [J].
Martin, CJ ;
Sutton, DG ;
Workman, A ;
Shaw, AJ ;
Temperton, D .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (852) :1283-1287
[10]   Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods [J].
Petoussi-Henss, N ;
Zankl, M ;
Drexler, G ;
Panzer, W ;
Regulla, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2237-2250