Reproducibility of the water-drinking test in patients with exfoliation syndrome and exfoliative glaucoma

被引:10
作者
Ozyol, Erhan [1 ]
Ozyol, Pelin [2 ]
Karalezli, Aylin [2 ]
机构
[1] Mugla Sitki Kocman Univ, Training & Res Hosp, Dept Ophthalmol, Mugla, Turkey
[2] Mugla Sitki Kocman Univ, Fac Med, Dept Ophthalmol, Mugla, Turkey
关键词
exfoliation syndrome; exfoliative glaucoma; intraocular pressure; intraocular pressure fluctuation; water-drinking test; ELEVATED INTRAOCULAR-PRESSURE; OPEN-ANGLE GLAUCOMA; FIXED-COMBINATION; DIAGNOSTIC-VALUE; OPEN-LABEL; TIMOLOL; 8-WEEK;
D O I
10.1111/aos.13132
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the reproducibility of intraocular pressure (IOP) peaks and fluctuations detected during the water-drinking test (WDT) in patients with exfoliation syndrome (XFS) and exfoliative glaucoma (XFG). MethodsThis prospective study included 34 XFS and 30 XFG patients. Each patient was evaluated twice, with the two WDTs performed on a 30-day interval. We recorded IOP peak (highest IOP during the WDT) and IOP fluctuation (IOP peak minus IOP before the test). Bland-Altman analysis was applied to assess the agreement of IOP peaks and fluctuations between the two consecutive visits. We defined reproducible as within 4 mmHg for IOP peak and within 2 mmHg for IOP fluctuation. ResultsThere were no significant differences in IOP values, IOP peaks and IOP fluctuations between the two visits for both XFS and XFG patients (p>0.05, for all). The coefficient of repeatability for IOP peak was 2.5mmHg and 3.5mmHg in XFS and XFG patients respectively and for IOP fluctuation, it was 2.1mmHg and 2.2mmHg. None of the XFS or XFG patients had an IOP peak difference higher than 4mmHg. Intraocular pressure (IOP) fluctuation differences above 2.0mmHg were found in 8.8% of XFS patients and 16.6% of XFG patients. ConclusionsIntraocular pressure (IOP) peak and IOP fluctuation have a reproducibility, both in XFS and in XFG.
引用
收藏
页码:E795 / E798
页数:4
相关论文
共 50 条
  • [31] Evaluation of the Effect of Duration on Retinal Nerve Fiber Layer Thickness and Choroidal Thickness in Exfoliation Syndrome and Exfoliative Glaucoma
    Toptan, Muesluem
    Simsek, Ali
    DIAGNOSTICS, 2023, 13 (02)
  • [32] Increased aqueous humor basic fibroblast growth factor and hyaluronan levels in relation to the exfoliation syndrome and exfoliative glaucoma
    Gartaganis, SP
    Georgakopoulos, CD
    Exarchou, AM
    Mela, EK
    Lamari, F
    Karamanos, NK
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (06): : 572 - 575
  • [33] The Effect of the Water Drinking Test on Ocular Parameters and Choroidal Thickness in Glaucoma Suspects
    Kandarakis, Stylianos A.
    Katsimpris, Andreas
    Kourti, Persefoni
    Psinakis, Filippos
    Karmiris, Efthymios
    Papakonstantinou, Evangelia
    Andreanos, Konstantinos
    Petrou, Petros
    Georgalas, Ilias
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [34] Aqueous humour levels of ghrelin in exfoliation syndrome and exfoliation glaucoma patients
    Ozec, Ayse Vural
    Dursun, Ayhan
    Toker, Mustafa Ilker
    Demirci, Yuksel
    Topalkara, Aysen
    Erdogan, Haydar
    Arici, Mustafa Kemal
    Ersalcan, Taner
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (04) : 348 - 352
  • [35] Aqueous humour levels of ghrelin in exfoliation syndrome and exfoliation glaucoma patients
    Ayşe Vural Özeç
    Ayhan Dursun
    Mustafa İlker Toker
    Yüksel Demirci
    Aysen Topalkara
    Haydar Erdoğan
    Mustafa Kemal Arıcı
    Taner Ersalcan
    Japanese Journal of Ophthalmology, 2014, 58 : 348 - 352
  • [36] Influence of the Water-Drinking Test on Intraocular Pressure, Schlemm's Canal, and Autonomic Nervous System Activity
    Chen, Wei
    Chen, Liugui
    Chen, Zhiqi
    Xiang, Yan
    Liu, Shiliang
    Zhang, Hong
    Wang, Junming
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (08) : 3232 - 3238
  • [37] Reproducibility of water drinking test performed at different times of the day
    Medina, Flavio Mac Cord
    Pereira Rodrigues, Fabricio Kafury
    Ponte Pierre Filho, Paulo de Tarso
    Matsuo, Tiemi
    Cabral de Vasconcellos, Jose Paulo
    Costa, Vital Paulino
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (03) : 283 - 290
  • [38] Comparison of Intraocular Pressure Changes During the Water Drinking Test Between Different Fluid Volumes in Patients With Primary Open-angle Glaucoma
    Susanna, Carolina N.
    Susanna, Remo, Jr.
    Hatanaka, Marcelo
    Susanna, Bianca N.
    Susanna, Fernanda N.
    De Moraes, Carlos G.
    JOURNAL OF GLAUCOMA, 2018, 27 (11) : 950 - 956
  • [39] Results for Water-drinking Test, before and after Laser Iridotomy, in Primary Angle-closure Suspects
    Razeghinejad, M. Reza
    Karampour, Parisa
    Masoumpour, Masoumeh Beigom
    Tajbakhsh, Zahra
    Nowroozzadeh, M. Hossein
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) : 150 - 154
  • [40] Correlation between central corneal thickness and intraocular pressure peak and fluctuation during the water drinking test in glaucoma patients
    Furlanetto, Rafael Lacerda
    Facio, Antonio Carlos, Jr.
    Hatanaka, Marcelo
    Susanna Junior, Remo
    CLINICS, 2010, 65 (10) : 967 - 970