Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema

被引:32
作者
Ibrahim, M. A. [1 ]
Sepah, Y. J. [1 ]
Symons, R. C. A. [1 ,2 ]
Channa, R. [1 ]
Hatef, E. [1 ]
Khwaja, A. [1 ]
Bittencourt, M. [1 ]
Heo, J. [1 ]
Do, D. V. [1 ]
Nguyen, Q. D. [1 ]
机构
[1] Johns Hopkins Univ, Retinal Imaging Res & Reading Ctr, Wilmer Eye Inst, Sch Med, Baltimore, MD 21287 USA
[2] Univ Kansas, Sch Med, Dept Ophthalmol, Prairie Village, KS USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; diabetic macular edema; time domain; spectral domain; STRATUS;
D O I
10.1038/eye.2011.293
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To report macular thickness values in normal eyes and eyes with diabetic macular edema (DME) using time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to derive a conversion equation. Methods The index study was a prospective investigation conducted on 80 eyes from 40 normal subjects and 130 eyes from 118 patients with DME seen in our clinic. Retinal thickness values from the central 1mm of the macula and surrounding four ETDRS subfields were acquired using TD-OCT (Stratus OCT) and SD-OCT (SPECTRALIS HRA+OCT). Measurements of the central (C) subfield from both devices were used to derive a conversion equation. The equation was used to predict SD-OCT values using measurements from TD-OCT. Agreement between predicted and actual SD-OCT measurements was assessed. Results In normal eyes, the mean difference between TD-OCT and SD-OCT measurements of the C subfield was 76 mu m (CI95=74 and 77, respectively). The conversion equation, y=1.029x+72.49, was derived. In eyes with DME, using the equation, SPECTRALIS-predicted values were 5% higher than actual measurements, with 95% of predicted values falling within 9% of the actual measurements. Relocating SD-OCT grids to match the location on TD-OCT resulted in predicted values falling within 7% of actual measurements. Conclusions The percent difference between actual thickness measurements from SPECTRALIS and predicted thickness measurements, using the conversion equation, was within reported limits of repeatability of Stratus in eyes with DME. Our equation may help correlate OCT values from both devices in standard care and clinical trials for DME. Eye (2012) 26, 454-462; doi: 10.1038/eye.2011.293; published online 2 December 2011
引用
收藏
页码:454 / 462
页数:9
相关论文
共 18 条
[1]   Comparison of the clinical diagnosis of diabetic macular edema with diagnosis by optical coherence tomography [J].
Browning, DJ ;
McOwen, MD ;
Bowen, RM ;
O'Marah, TL .
OPHTHALMOLOGY, 2004, 111 (04) :712-715
[2]   Correlation in foveal thickness measurements between spectral-domain and time-domain optical coherence tomography in normal individuals [J].
Carpineto, P. ;
Nubile, M. ;
Toto, L. ;
Gnama, A. Aharrh ;
Marcucci, L. ;
Mastropasqua, L. ;
Ciancaglini, M. .
EYE, 2010, 24 (02) :251-258
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema [J].
Forooghian, Farzin ;
Cukras, Catherine ;
Meyerle, Catherine B. ;
Chew, Emily Y. ;
Wong, Wai T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4290-4296
[6]   Comparison of time domain Stratus OCT and spectral domain SLO/OCT for assessment of macular thickness and volume [J].
Forte, R. ;
Cennamo, G. L. ;
Finelli, M. L. ;
de Crecchio, G. .
EYE, 2009, 23 (11) :2071-2078
[7]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706
[8]   Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography [J].
Grover, Sandeep ;
Murthy, Ravi K. ;
Brar, Vikram S. ;
Chalam, Kakarla V. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) :2644-2647
[9]   Normative Data for Macular Thickness by High-Definition Spectral-Domain Optical Coherence Tomography (Spectralis) [J].
Grover, Sandeep ;
Murthy, Ravi K. ;
Brar, Vikram S. ;
Chalam, Kakarla V. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) :266-271
[10]   Comparison of Spectral- and Time-Domain Optical Coherence Tomography for Retinal Thickness Measurements in Healthy and Diseased Eyes [J].
Han, Ian C. ;
Jaffe, Glenn J. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) :847-858