Stability of urine specimens stored with and without preservatives at room temperature and on ice prior to urinalysis

被引:28
作者
Ercan, Mujgan [1 ]
Akbulut, Emis Deniz [2 ]
Abusoglu, Sedat [3 ]
Yilmaz, Fatma Meric [4 ]
Oguz, Esra Firat [4 ]
Topcuoglu, Canan [4 ]
Oztekin, Volkan [5 ]
Bogdaycioglu, Nihal [4 ]
机构
[1] Publ Hlth Lab, Dept Biochem, Aydin, Turkey
[2] Turkiye Yuksek Ihtisas Educ & Res Hosp, Clin Biochem, Ankara, Turkey
[3] Selcuk Univ, Dept Biochem, Fac Med, Konya, Turkey
[4] Ankara Numune Training & Res Hosp, Clin Biochem Lab, Ankara, Turkey
[5] Ankara Numune Training & Res Hosp, Urol Clin, Ankara, Turkey
关键词
Preanalytic phase; Urinalysis; Preservative tube; COUNTS;
D O I
10.1016/j.clinbiochem.2015.05.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Design and methods: Fresh urine specimen (n = 48) aliquots in BD Vacutainer (R) Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8 h. Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72 h, while two aliquots were kept on ice for 4 and 8 h. Results: There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72 h and red blood cells (RBCs) at 72 h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8 h. Conclusions: A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8 h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 922
页数:4
相关论文
共 11 条
[1]   AUTOMATED URINALYSIS [J].
CARLSON, DA ;
STATLAND, BE .
CLINICS IN LABORATORY MEDICINE, 1988, 8 (03) :449-461
[2]  
Clinical and Laboratory Standards Institute, 2013, GP16A3 NCCLS CLIN LA
[3]   THE PRE-ANALYTICAL CHALLENGES OF ROUTINE URINALYSIS [J].
Coppens, A. ;
Speeckaert, M. ;
Delanghe, J. .
ACTA CLINICA BELGICA, 2010, 65 (03) :182-189
[4]   Preanalytical requirements of urinalysis [J].
Delanghe, Joris ;
Speeckaert, Marijn .
BIOCHEMIA MEDICA, 2014, 24 (01) :89-104
[5]   FALSELY NEGATIVE URINARY LEUKOCYTE COUNTS DUE TO DELAYED EXAMINATION [J].
KIERKEGAARD, H ;
FELDTRASMUSSEN, U ;
HORDER, M ;
ANDERSEN, HJ ;
JORGENSEN, PJ .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (03) :259-261
[6]  
Kouri T, 2002, CLIN CHEM, V48, P900
[7]   Limits of preservation of samples for urine strip tests and particle counting [J].
Kouri, Timo ;
Malminiemi, Outi ;
Penders, Joris ;
Pelkonen, Virpi ;
Vuotari, Lotta ;
Delanghe, Joris .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (05) :703-713
[8]   Preanalytical quality improvement: in quality we trust [J].
Lippi, Giuseppe ;
Becan-McBride, Kathleen ;
Behulova, Darina ;
Bowen, Raffick A. ;
Church, Stephen ;
Delanghe, Joris ;
Grankvist, Kjell ;
Kitchen, Steve ;
Nybo, Mads ;
Nauck, Matthias ;
Nikolac, Nora ;
Palicka, Vladimir ;
Plebani, Mario ;
Sandberg, Sverre ;
Simundic, Ana-Maria .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (01) :229-241
[9]  
Manoni SV F, 2008, STABILITY COMMON ANA, P192
[10]  
Miller B.F., 2009, NEW EVALUATION BD VA, P1