Comparison of two new generation influenza rapid diagnostic tests with instrument-based digital readout systems for influenza virus detection

被引:23
作者
Ryu, S. -W. [1 ]
Lee, J. -H. [2 ]
Kim, J. [3 ]
Jang, M. -A. [3 ]
Nam, J. -H. [3 ]
Byoun, M. -S. [3 ]
Lim, C. S. [3 ]
机构
[1] Kangwon Natl Univ, Sch Med, Dept Lab Med, Chunchon, South Korea
[2] Osan Hankook Gen Hosp, Dept Lab Med, Osan, South Korea
[3] Korea Univ, Dept Lab Med, Coll Med, Seoul, South Korea
关键词
Influenza; instrument-based digital readout system; rapid diagnostic test; real-time PCR; PLUS B; A/B VIRUS; RT-PCR; ASSAY; SENSITIVITY; PERFORMANCE; FLU;
D O I
10.1080/09674845.2016.1189026
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Influenza rapid diagnostic tests (RDTs) have been developed to supply scientists with more sensitive and specific techniques. Newly developed digital reader-based techniques require test evaluations before their clinical application.Methods: Two types of digital influenza RDTs using a digital readout system and one conventional RDT were compared using 314 nasopharyngeal swabs of influenza. The swabs originated from symptomatic individuals suspected of influenza infection, and the presence of influenza was confirmed with influenza real-time polymerase chain reaction (PCR) testing and influenza subtyping. Methods were the Sofia (R) Influenza A+B Fluorescence Immunoassay (FIA), which uses a portable fluorescence analyser, the BD Veritor System Flu A+B, which uses a colorimetric immunochromatographic method with a reflectance-based measurement digital device, and the SD Bioline assay, which is based on a traditional immunochromatographic method.Results: The Sofia (R) Influenza A+B system, the BD Veritor System Flu A+B and the SD Bioline assay showed sensitivities in relative real-time PCR results of 74.2, 73.0 and 53.9%, respectively, for influenza A, and 82.5, 72.8 and 71.0%, respectively, for influenza B. All three RDTs showed 100% specificities for influenza A and influenza B. The Sofia (R) Influenza A+B Fluorescence Immunoassay showed sensitive and specific results for the detection of influenza B in contrast to the BD Veritor System Flu A+B. The two digital RDTs showed higher sensitivity and specificity than the conventional RDT in the detection of the influenza H3 subtype.Conclusions: Digital-based readout systems for the detection of the influenza virus can be applied for more sensitive diagnosis in clinical settings than conventional RDTs.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 11 条
  • [1] Alexander R, 2005, COMMUN DIS INTELL, V29, P272
  • [2] Factors affecting QuickVue Influenza A plus B rapid test performance in the community setting
    Cheng, Calvin K. Y.
    Cowling, Benjamin J.
    Chan, Kwok Hung
    Fang, Vicky J.
    Seto, Wing Hong
    Yung, Raymond
    Uyeki, Timothy M.
    Houck, Peter M.
    Peiris, J. S. Malik
    Leung, Gabriel M.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 65 (01) : 35 - 41
  • [3] Evaluation of a novel real-time RT-PCR using TOCE technology compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses
    Cho, Chi Hyun
    Chulten, Bayarjavkhlan
    Lee, Chang Kyu
    Nam, Myung Hyun
    Yoon, Soo Young
    Lim, Chae Seung
    Cho, Yunjung
    Kim, Young Kee
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (04) : 338 - 342
  • [4] Evaluation of five rapid diagnostic kits for influenza A/B virus
    Cho, Chi Hyun
    Woo, Mi Kyung
    Kim, Ju Yeon
    Cheong, Seok
    Lee, Chang-Kyu
    An, SeongSoo A.
    Lim, Chae Seung
    Kim, Woo Joo
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (01) : 51 - 56
  • [5] Evaluation and Verification of the Nanosphere Verigene RV plus Assay for Detection of Influenza A/B and H1/H3 Subtyping
    Cho, Han Jin
    Jang, Jin Woo
    Ko, Sun Young
    Choi, Sung Hyuk
    Lim, Chae Seung
    An, Seong Soo A.
    [J]. JOURNAL OF MEDICAL VIROLOGY, 2015, 87 (01) : 18 - 24
  • [6] Analytical and Clinical Sensitivity of the 3M Rapid Detection Influenza A+B Assay
    Dale, Suzanne E.
    Mayer, Christine
    Mayer, Marie C.
    Menegus, Marilyn A.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (11) : 3804 - 3807
  • [7] Prompt detection of influenza A and B viruses using the BD Veritor™ System Flu A plus B, Quidele® Sofia® Influenza A plus B FIA, and Alere BinaxNOW® Influenza A&B compared to real-time reverse transcription-polymerase chain reaction (RT-PCR)
    Dunn, Jim
    Obuekwe, Joy
    Baun, Traci
    Rogers, Justin
    Patel, Twinkle
    Snow, Linda
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 79 (01) : 10 - 13
  • [8] Evaluation of Sofia fluorescent immunoassay analyzer for influenza A/B virus
    Lee, Chang Kyu
    Cho, Chi Hyun
    Woo, Mi Kyung
    Nyeck, Agnes E.
    Lim, Chae Seung
    Kim, Woo Joo
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2012, 55 (03) : 239 - 243
  • [9] Clinical performance evaluation of the BD Veritor System Flu A plus B assay
    Nam, Myung-Hyun
    Jang, Jin Woo
    Lee, Jong-Han
    Cho, Chi Hyun
    Lim, Chae Seung
    Kim, Woo Joo
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2014, 204 : 86 - 90
  • [10] Low Sensitivity of Rapid Diagnostic Test for Influenza
    Uyeki, Timothy M.
    Prasad, Ramakrishna
    Vukotich, Charles
    Stebbins, Samuel
    Rinaldo, Charles R.
    Ferng, Yu-hui
    Morse, Stephen S.
    Larson, Elaine L.
    Aiello, Allison E.
    Davis, Brian
    Monto, Arnold S.
    [J]. CLINICAL INFECTIOUS DISEASES, 2009, 48 (09) : E89 - E92