Development of heavy-ion radiotherapy technology with HIMAC

被引:1
作者
Noda, Koji [1 ]
机构
[1] Natl Inst Radiol Sci, Dept Accelerator & Med Phys, 4-9-1 Anagawa, Chiba, Chiba 2638555, Japan
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15) | 2016年 / 44卷
关键词
Beam-wobbling method; Phase-controlled rescanning; Superconducting rotating gantry; MULTIPLE-ENERGY OPERATION; MOVING TARGET IRRADIATION; KNOCKOUT SLOW-EXTRACTION; PROTON RADIOTHERAPY; SCANNING SYSTEM; RADIATION-THERAPY; INTENSITY CONTROL; CANCER-THERAPY; SPILL RIPPLE; BEAM;
D O I
10.1142/S2010194516602192
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Since 1994, HIMAC has carried out clinical studies and treatments for more than 9000 cancer patients with carbon-ion beams. During the first decade of the HIMAC study, a single beam-wobbling method, adopted as the HIMAC beam-delivery technique, was improved for treatments of moving tumors and for obtaining more conformal dose distribution. During the second decade, a pencil-beam 3D scanning method has been developed toward an "adaptive cancer treatment" for treatments of both static and moving tumors. A new treatment research facility was constructed with HIMAC in order to verify the developed 3D scanning technology through a clinical study that has been successfully conducted since 2011. As the next stage, a compact heavy-ion rotating gantry with a superconducting technology has been developed for the more accurate and shorter-course treatments. The twenty-year development of the heavy-ion radiotherapy technologies including accelerator technologies with HIMAC is reviewed.
引用
收藏
页数:10
相关论文
共 35 条
  • [31] THE 200-MEV PROTON THERAPY PROJECT AT THE PAUL-SCHERRER-INSTITUTE - CONCEPTUAL DESIGN AND PRACTICAL REALIZATION
    PEDRONI, E
    BACHER, R
    BLATTMANN, H
    BOHRINGER, T
    CORAY, A
    LOMAX, A
    LIN, SX
    MUNKEL, G
    SCHEIB, S
    SCHNEIDER, U
    TOUROVSKY, A
    [J]. MEDICAL PHYSICS, 1995, 22 (01) : 37 - 53
  • [32] Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4
    Pshenichnov, Igor
    Mishustin, Igor
    Greiner, Walter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23) : 6099 - 6112
  • [33] Dynamic intensity control system with RF-knockout slow-extraction in the HIMAC synchrotron
    Sato, Shinji
    Furukawa, Takuji
    Noda, Koji
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02) : 226 - 231
  • [34] A Review of Update Clinical Results of Carbon Ion Radiotherapy
    Tsujii, Hirohiko
    Kamada, Tadashi
    [J]. JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2012, 42 (08) : 670 - 685
  • [35] Adaptive radiation therapy
    Yan, D
    Vicini, F
    Wong, J
    Martinez, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) : 123 - 132