Functional results of angular-stable plate fixation in displaced proximal humeral fractures

被引:65
作者
Handschin, Alexander E. [1 ]
Cardell, Markus [1 ]
Contaldo, Claudio [1 ]
Trentz, Otmar [1 ]
Wanner, Guido A. [1 ]
机构
[1] Univ Zurich Hosp, Div Trauma Surg, CH-8091 Zurich, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2008年 / 39卷 / 03期
关键词
proximal humeral fracture; angular-stable; PHILOS; tubular plate;
D O I
10.1016/j.injury.2007.10.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The availability of angular-stable plate/screw systems led to a euphoric use of these implants for the treatment of displaced proximal humerus fractures. The high implant costs seem to be justified by a potentially improved outcome. Patients and methods: Thirty one patients (20 female, 11 mate, mean age: 62 16 years) with two-, three- and four-part proximal humerus fractures (Neer classification) were operated using the proximal humeral internal locking system (PHILOS). The mean follow-up time was 19 3 postoperative months (range: 340-720 days). Functional results (Constant score, UCLA-score) were analysed and compared to an equivalent historic control group of 60 patients operated for the same fracture types using two one-third tubular plates. Additionally, total implant costs for each technique were compared. Results: Complications in the PHILOS group included one implant failure with refracture, one secondary dislocation, two cases of subacromial. impingement, and two cases of partial avascular necrosis of the humeral. head. The mean Constant score (age- and sex-matched) was 80 +/- 11% for the affected side and 104 +/- 13% for the healthy side. The UCLA scores were excellent in 10%, good in 67%, and fair in 23% of the patients. Complication rate and functional results did not differ significantly from the control group treated with one-third tubular plates. Implant costs were significantly higher for the PHILOS group (684 +/- 40 Euro vs. 158 +/- 20 Euro, p < 0.05). Conclusion: Our study showed similar functional results using either plate. Although the PHILOS plate may provide important advantages in specific situations, such as osteoporotic bone, its use as a standard must be carefully judged under the economic aspect of the significant higher implant costs. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:306 / 313
页数:8
相关论文
共 28 条
[1]   Four part fractures of the proximal humerus [J].
Bhandari, M ;
Matthys, G ;
McKee, MD .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (02) :126-127
[2]   Internal fixation of proximal humeral fractures with a locking compression plate -: A retrospective evaluation of 72 patients followed for a minimum of 1 year [J].
Björkenheim, JM ;
Pajarinen, J ;
Savolainen, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :741-745
[3]   BLADE PLATE FIXATION - TECHNIC SUITABLE FOR FRACTURES OF THE SURGICAL NECK OF THE HUMERUS AND SIMILAR LESIONS [J].
BOSWORTH, DM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1949, 141 (16) :1111-1113
[4]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[5]   Evidenzbasierte Unfallchirurgie [J].
F. Eitel ;
E. A. M. Neugebauer ;
W. E. Mutschler .
Der Unfallchirurg, 2002, 105 (8) :666-674
[6]   REPAIR OF THE ROTATOR CUFF - END-RESULT STUDY OF FACTORS INFLUENCING RECONSTRUCTION [J].
ELLMAN, H ;
HANKER, G ;
BAYER, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (08) :1136-1144
[7]  
ESSER RD, 1994, CLIN ORTHOP RELAT R, V299, P244
[8]  
GERBER C, 1990, ORTHOPADE, V19, P316
[9]   The clinical relevance of posttraumatic avascular necrosis of the humeral head [J].
Gerber, C ;
Hersche, O ;
Berberat, C .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) :586-590
[10]  
Hessmann M, 1998, ACTA CHIR BELG, V98, P212