Study on the transmission mechanism for wearable device using the human body as a transmission channel

被引:48
作者
Fujii, K
Takarashi, M
Ito, K
Hachisuka, K
Terauchi, Y
Kishi, Y
Sasaki, K
Itao, K
机构
[1] Chiba Univ, Grad Sch Sci & Technol, Chiba 2638522, Japan
[2] Chiba Univ, Res Ctr Frontier Med Engn, Chiba 2638522, Japan
[3] Univ Tokyo, Grad Sch Frontier Sci, Dept Environm Studies, Tokyo 1138656, Japan
[4] Tokyo Univ Sci, Tokyo 1628601, Japan
关键词
personal area network; intra-body communication; human body; phantom; FDTD;
D O I
10.1093/ietcom/e88-b.6.2401
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, wearable devices which use the human body as a transmission channel have been developed. However, there has been a lack of information related the transmission mechanism of such devices in the physical layer. Electro-magnetic communication trials using human body as transmission media have more than a decade's history. However, most of the researches have been conducted by researchers who just want to utilize the fact and practically no physical mechanisms have been researched until recently. Hence, in previous study, the authors proposed calculation models of the wearable transmitter and the receiver attached to the arm using the FDTD method. Moreover, the authors compared the calculated received signal levels to the measured ones by using a biological tissue-equivalent phantom. However, there was little analysis on each component of the propagated signal. In this paper, the authors clarified the transmission mechanism of the wearable device using the human body as a transmission channel from the view point of the interaction between electromagnetic wave and the human body. First, the authors focused their attention on measuring the each component of the propagated signal using a shielded loop antenna. From these results, the favorable direction of electrodes of the transmitter was proposed to use the human body as a transmission channel. As a result, longitudinal direction is effective for sending the signal to the receiver, compared to the transversal direction. Next, the authors investigated the dominant signal transmission channel, because the question of whether the dominant signal channel is in or around the arm had remained unsettled. To clear this question, the authors proposed the calculation model of an arm wearing the transmitter and receiver placed into a hole of a conductor plate. The electric field distribution and received signal voltage was investigated as a function of the gap between the hole of the conductor plate and the surface of the arm. The result indicated that the dominant signal transmission channel is not inside but the surface of the arm because signal seems to be distributed as a surface wave.
引用
收藏
页码:2401 / 2410
页数:10
相关论文
共 10 条
[1]  
[Anonymous], P IEEE INT S ANT PRO
[2]  
Doi K., 2001, P HUM INT S, P389
[3]  
FUJII K, 2004, IEICE T COMMUN, V87, P1383
[4]  
FUKUMOTO M, 1997, P ACM C HUM FACT COM, P147
[5]   Development of wearable intra-body communication devices [J].
Hachisuka, K ;
Nakata, A ;
Takeda, T ;
Shiba, K ;
Sasaki, K ;
Hosaka, H ;
Itao, K .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 105 (01) :109-115
[6]  
Handa T, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P1003, DOI 10.1109/SENSOR.1997.635344
[7]   Wearable key: Device for personalizing nearby environment [J].
Matsushita, N ;
Tajima, S ;
Ayatsuka, Y ;
Rekimoto, J .
FOURTH INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, DIGEST OF PAPERS, 2000, :119-126
[8]  
Shinagawa M, 2003, IEEE IMTC P, P296
[9]   THE COMPUTER FOR THE 21ST-CENTURY [J].
WEISER, M .
SCIENTIFIC AMERICAN, 1991, 265 (03) :94-&
[10]  
Zimmerman T. G., 1995, PERSONAL AREA NETWOR