Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography

被引:167
|
作者
Leetmaa, Tina [1 ]
Hansson, Nicolaj C. [1 ]
Leipsic, Jonathon [3 ,4 ]
Jensen, Kaare [1 ]
Poulsen, Steen H. [1 ]
Andersen, Henning R. [1 ]
Jensen, Jesper M. [1 ]
Webb, John [3 ,4 ]
Blanke, Philipp [3 ,4 ]
Tang, Mariann [2 ]
Norgaard, Bjarne L. [1 ]
机构
[1] Aarhus Univ Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp Skejby, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Univ British Columbia, St Pauls Hosp, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Radiol, St Pauls Hosp, Vancouver, BC, Canada
关键词
aortic valve stenosis; multislice computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; REPLACEMENT; POSITION; CT; BIOPROSTHESES; REGURGITATION; THROMBOLYSIS; DYSFUNCTION; RESTENOSIS; STENOSIS;
D O I
10.1161/CIRCINTERVENTIONS.114.001596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. Methods and Results-MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. Conclusions-Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Early Transcatheter Aortic Valve Thrombosis
    Greason, Kevin L.
    Mathew, Verghese
    Sarano, Maurice E.
    Maleszewski, Joseph J.
    Suri, Rakesh M.
    Rihal, Charanjit S.
    JOURNAL OF CARDIAC SURGERY, 2013, 28 (03) : 264 - 266
  • [32] Assessment of the Geometric Interaction Between the Lotus Transcatheter Aortic Valve Prosthesis and the Native Ventricular Aortic Interface by 320-Multidetector Computed Tomography
    Gooley, Robert P.
    Cameron, James D.
    Meredith, Ian T.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) : 740 - 749
  • [33] Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation
    de Morais, Gustavo Pires
    Bettencourt, Nuno
    Silva, Guida
    Ferreira, Nuno
    Sousa, Olga
    Caeiro, Daniel
    Rocha, Joao
    Carvalho, Monica
    Leite, Daniel
    Braga, Pedro
    Fonseca, Conceicao
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2011, 30 (09) : 717 - 726
  • [34] Iodine contrast volume reduction in preoperative transcatheter aortic valve implantation computed tomography: Comparison with 64and 256-multidetector row computed tomography
    Yoshiura, T.
    Masuda, T.
    Kobayashi, Y.
    Kikuhara, Y.
    Ishibashi, T.
    Nonaka, H.
    Oku, T.
    Sato, T.
    Funama, Y.
    RADIOGRAPHY, 2024, 30 (01) : 408 - 415
  • [35] Prognostic value of contrast-enhanced computed tomography in acute pancreatitis
    Jakchairoongruang, Ketsuda
    Arjhansiri, Kiat
    ASIAN BIOMEDICINE, 2013, 7 (03) : 357 - 364
  • [36] Computed tomography anatomical characteristics based on transcatheter aortic valve replacement in aortic regurgitation
    Chen, Yang
    Zhao, Jie
    Liu, Qingrong
    Zhang, Hongliang
    Wang, Moyang
    Niu, Guannan
    Feng, Dejing
    Lv, Bin
    Xu, Haiyan
    Song, Guangyuan
    Wu, Yongjian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (10) : 2063 - 2071
  • [37] Case Report: The value of contrast-enhanced ultrasound and contrast-enhanced computed tomography in the diagnosis of hepatic angiosarcoma
    Wang, Feiqian
    Numata, Kazushi
    Liang, Hua
    Tsuchiya, Hiromi
    Ruan, Litao
    Tanabe, Mikiko
    Bai, Xiaofang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [38] Value of Contrast-Enhanced Ultrasonography in Assessing the Vascularity of Liver Metastases Comparison With Contrast-Enhanced Computed Tomography
    Zheng, Yan-Ling
    Yin, Xiao-Yu
    Xie, Xiao-Yan
    Xu, Hui-Xiong
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Liang, Jin-Yu
    Lu, Ming-De
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (10) : 1403 - 1410
  • [39] Calcium scoring of aortic valve calcification in aortic valve stenosis with a multislice computed tomography scanner:: Non-enhanced versus contrast-enhanced studies
    Mühlenbruch, G
    Wildberger, JE
    Koos, R
    Das, A
    Thomas, C
    Ruhl, K
    Niethammer, M
    Floh, TG
    Stanzel, S
    Günther, RW
    Mahnken, AH
    ACTA RADIOLOGICA, 2005, 46 (06) : 561 - 566
  • [40] Radiation dose and repeatability of aortic valve measurement by multidetector row computed tomography to assess eligibility for transcatheter aortic valve implantation
    Kedzierski, Bartlomiej
    Gac, Pawel
    Glosna, Martyna
    Poreba, Rafal
    Pawlas, Krystyna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 29 (08): : 983 - 992