Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography

被引:167
|
作者
Leetmaa, Tina [1 ]
Hansson, Nicolaj C. [1 ]
Leipsic, Jonathon [3 ,4 ]
Jensen, Kaare [1 ]
Poulsen, Steen H. [1 ]
Andersen, Henning R. [1 ]
Jensen, Jesper M. [1 ]
Webb, John [3 ,4 ]
Blanke, Philipp [3 ,4 ]
Tang, Mariann [2 ]
Norgaard, Bjarne L. [1 ]
机构
[1] Aarhus Univ Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp Skejby, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Univ British Columbia, St Pauls Hosp, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Radiol, St Pauls Hosp, Vancouver, BC, Canada
关键词
aortic valve stenosis; multislice computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; REPLACEMENT; POSITION; CT; BIOPROSTHESES; REGURGITATION; THROMBOLYSIS; DYSFUNCTION; RESTENOSIS; STENOSIS;
D O I
10.1161/CIRCINTERVENTIONS.114.001596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. Methods and Results-MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. Conclusions-Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantification of Aortic Valve Calcification in Contrast-Enhanced Computed Tomography
    Laohachewin, Danai
    Ruile, Philipp
    Breitbart, Philipp
    Minners, Jan
    Jander, Nikolaus
    Soschynski, Martin
    Schlett, Christopher L.
    Neumann, Franz-Josef
    Westermann, Dirk
    Hein, Manuel
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [2] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [3] Quantification of aortic valve calcification on contrast-enhanced CT of patients prior to transcatheter aortic valve implantation
    Eberhard, Matthias
    Mastalerz, Monika
    Frauenfelder, Thomas
    Tanner, Felix C.
    Maisano, Francesco
    Nietlispach, Fabian
    Seifert, Burkhardt
    Alkadhi, Hatem
    Thi Dan Linh Nguyen-Kim
    EUROINTERVENTION, 2017, 13 (08) : 921 - 927
  • [4] Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement: A Comparison With Contrast-Enhanced Computed Tomography
    Suh, Young Joo
    Lee, Sak
    Hong, Geu-Ru
    Ko, Young-Guk
    Hong, Myeong-Ki
    Kim, Young Jin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 50 - 55
  • [5] Subclinical Leaflet Thrombosis in Transcatheter Aortic Valve Replacement Detected by Multidetector Computed Tomography - A Review of Current Evidence
    Rashid, Hashrul N.
    Brown, Adam J.
    McCormick, Liam M.
    Amiruddin, Ameera S.
    Be, Kim K.
    Cameron, James D.
    Nasis, Arthur
    Gooley, Robert P.
    CIRCULATION JOURNAL, 2018, 82 (07) : 1735 - 1742
  • [6] Multidetector computed tomography evaluation of candidates for transcatheter aortic valve implantation
    Guillen Subiran, M. E.
    Ros Mendoza, L. H.
    Angulo Hervias, E.
    Yaguee Romeo, D.
    Nunez Motilva, M. E.
    RADIOLOGIA, 2018, 60 (01): : 24 - 38
  • [7] Sinus of Valsalva Thrombosis Detected on Computed Tomography after Transcatheter Aortic Valve Replacement
    Lim, Su Jin
    Koo, Hyun Jung
    Jung, Seung Chai
    Kang, Do-Yoon
    Ahn, Jung-Min
    Park, Duk-Woo
    Park, Seung-Jung
    Yang, Dong Hyun
    Kang, Joon-Won
    KOREAN CIRCULATION JOURNAL, 2020, 50 (07) : 572 - 582
  • [8] Multidetector Computed Tomography to Facilitate Transcatheter Aortic Valve Implantation
    Leipsic J.
    Wood D.A.
    Gurvitch R.
    Hague C.J.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 457 - 467
  • [9] Multidetector computed tomography in Transcatheter aortic valve implantation. Where we stand
    Al-Hassan, D.
    Blanke, P.
    Leipsic, J.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (04): : 407 - 427
  • [10] Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience
    Le Couteulx, S.
    Caudron, J.
    Dubourg, B.
    Cauchois, G.
    Dupre, M.
    Michelin, P.
    Durand, E.
    Eltchaninoff, H.
    Dacher, J-N
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (05) : 279 - 289