Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography

被引:170
作者
Leetmaa, Tina [1 ]
Hansson, Nicolaj C. [1 ]
Leipsic, Jonathon [3 ,4 ]
Jensen, Kaare [1 ]
Poulsen, Steen H. [1 ]
Andersen, Henning R. [1 ]
Jensen, Jesper M. [1 ]
Webb, John [3 ,4 ]
Blanke, Philipp [3 ,4 ]
Tang, Mariann [2 ]
Norgaard, Bjarne L. [1 ]
机构
[1] Aarhus Univ Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp Skejby, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Univ British Columbia, St Pauls Hosp, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Radiol, St Pauls Hosp, Vancouver, BC, Canada
关键词
aortic valve stenosis; multislice computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; REPLACEMENT; POSITION; CT; BIOPROSTHESES; REGURGITATION; THROMBOLYSIS; DYSFUNCTION; RESTENOSIS; STENOSIS;
D O I
10.1161/CIRCINTERVENTIONS.114.001596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. Methods and Results-MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. Conclusions-Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
引用
收藏
页数:8
相关论文
共 31 条
[1]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[2]   Guidelines for reporting mortality and morbidity after cardiac valve interventions [J].
Akins, Cary W. ;
Miller, D. Craig ;
Turina, Marko I. ;
Kouchoukos, Nicholas T. ;
Blackstone, Eugene H. ;
Grunkemeier, Gary L. ;
Takkenberg, Johanna J. M. ;
David, Tirone E. ;
Butchart, Eric G. ;
Adams, David H. ;
Shahian, David M. ;
Hagl, Siegfried ;
Mayer, John E. ;
Lytle, Bruce W. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04) :732-738
[3]   Embolization from biological prosthetic aortic root [J].
Anselmino, Monica ;
Andria, Anna .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (03) :228-229
[4]   Underexpansion and Ad Hoc Post-Dilation in Selected Patients Undergoing Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Leipsic, Jonathon ;
Binder, Ronald ;
Dvir, Danny ;
Tan, John ;
Freeman, Melanie ;
Norgaard, Bjarne ;
Hansson, Nicolaj ;
Cheung, Anson ;
Ye, Jian ;
Yang, Tae-Hyun ;
Maryniak, Kasia ;
Raju, Rekha ;
Thompson, Angus ;
Blanke, Philipp ;
Lauck, Sandra ;
Wood, David ;
Webb, John .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (10) :976-981
[5]   Impact of Post-Implant SAPIEN XT Geometry and Position on Conduction Disturbances, Hemodynamic Performance, and Paravalvular Regurgitation [J].
Binder, Ronald K. ;
Webb, John G. ;
Toggweiler, Stefan ;
Freeman, Melanie ;
Barbanti, Marco ;
Willson, Alexander B. ;
Alhassan, Donya ;
Hague, Cameron J. ;
Wood, David A. ;
Leipsic, Jonathon .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) :462-468
[6]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[7]   CT in Transcatheter Aortic Valve Replacement [J].
Blanke, Philipp ;
Schoepf, U. Joseph ;
Leipsic, Jonathon A. .
RADIOLOGY, 2013, 269 (03) :650-669
[8]   Cardiac CT Assessment of Prosthetic Aortic Valve Dysfunction Secondary to Acute Thrombosis and Response to Thrombolysis [J].
Chan, Jonathan ;
Marwan, Mohamed ;
Schepis, Taziano ;
Ropers, Dieter ;
Du, Leanne ;
Achenbach, Stephan .
CIRCULATION, 2009, 120 (19) :1933-1934
[9]   Bioprostheses "Thrombosis" After Transcatheter Aortic Valve Replacement [J].
Cota, Linda ;
Stabile, Eugenio ;
Agrusta, Marco ;
Sorropago, Giovanni ;
Pucciarelli, Armando ;
Ambrosini, Vittorio ;
Mottola, Gaetano ;
Esposito, Giovanni ;
Rubino, Paolo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (07) :789-791
[10]   Recommendations for transoesophageal echocardiography: update 2010 [J].
Flachskampf, F. A. ;
Badano, L. ;
Daniel, W. G. ;
Feneck, R. O. ;
Fox, K. F. ;
Fraser, Alan G. ;
Pasquet, Agnes ;
Pepi, M. ;
de Isla, L. Perez ;
Zamorano, J. L. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (07) :557-576