Robust technique for accurate estimation of single-phase grid voltage fundamental frequency and amplitude

被引:14
作者
Reza, Md. Shamim [1 ]
Ciobotaru, Mihai
Agelidis, Vassilios Georgios
机构
[1] Univ New S Wales, Australian Energy Res Inst, Sydney, NSW 2052, Australia
关键词
power grids; frequency estimation; IIR filters; signal generators; least squares approximations; robust technique; single-phase grid voltage fundamental frequency estimation; single-phase grid voltage fundamental amplitude estimation; quadrature signal generator; QSG; fixed frequency tuned second-order generalised integrator; infinite-impulse-response differentiation filter; DF; instantaneous phase angle; generated orthogonal voltage waveforms; tuning process; direct current offset; fixed frequency tuned SOGI; least-squares method; POWER-SYSTEM FREQUENCY; ADAPTIVE PHASOR; LOCKED LOOP; ALGORITHMS; CONVERTERS; SCHEMES;
D O I
10.1049/iet-gtd.2014.0107
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study proposes a robust technique for accurate estimation of single-phase grid voltage fundamental amplitude and frequency. The technique relies on a quadrature signal generator (QSG) based on a fixed frequency tuned second-order generalised integrator (SOGI) and an infinite-impulse-response differentiation filter (DF). The DF is used to estimate the fundamental frequency from the instantaneous phase angle obtained from the generated orthogonal voltage waveforms. The estimation technique is robust and offers an easy tuning process as there is no interdependent loop between the orthogonal voltage system and the frequency estimation. Additionally, the technique is computationally efficient and can also reject the negative effects caused by the direct current offset and harmonics. Furthermore, the frequency estimation is less sensitive to harmonics when compared with a similar technique relying on the QSG based on the fixed frequency tuned SOGI and least-squares method. Simulation and real-time experimental results are provided to validate the robustness of the proposed technique.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 1547 IEEE
[2]  
[Anonymous], 1999, European Standard EN-50160
[3]  
[Anonymous], 2003, document IEC 61000-4-30
[4]  
[Anonymous], 2004, Photovoltaic (PV) SystemsCharacteristics of the Utility Interface
[5]  
[Anonymous], 2002, 61000413 IEC
[6]  
[Anonymous], 2005, 1453 IEEE
[7]  
[Anonymous], 2009, 1159 IEEE
[8]  
[Anonymous], 2002, 6100047 IEC
[9]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[10]   Practical considerations for recursive DFT implementation in numerical relays [J].
Darwish, Hatem A. ;
Fikri, Magdy .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) :42-49