Matrix and Bioabsorbable polymeric coils accelerate healing of intracranial aneurysms - Long-term experimental study

被引:174
作者
Murayama, Y
Tateshima, S
Gonzalez, NR
Vinuela, F
机构
[1] Univ Calif Los Angeles, Devid Geffen Sch Med, Dept Radiol Sci, Div Intervent Neuroradiol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Leo G Rigler Radiol Res Ctr, Los Angeles, CA 90095 USA
关键词
animal models; endovascular therapy; intracranial aneurysm; polymers; swine;
D O I
10.1161/01.STR.0000083394.33633.C2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Acceleration of intra-aneurysmal clot organization and fibrosis may be a solution to preventing aneurysm recanalization after endovascular treatment. The purpose of this study was to evaluate the short-term efficacy and long-term safety of the new Matrix coil system. Methods-Matrix coils consist of thin platinum coils covered with a bioabsorbable, polymeric material (polyglycolic acid/lactide). Fifty-two experimental aneurysms were created in 26 swine. All of the aneurysms were tightly packed with Matrix or Guglielmi detachable coils (GDC). Comparative angiographic and histopathologic data were analyzed at 2 weeks (n=14), 3 months (n=6), and 6 months (n=6) after embolization. Results-Three aneurysms treated with GDC ruptured despite tight packing. No recanalization or rupturing was observed in the aneurysms embolized with Matrix coils. At 14 days after embolization, the aneurysms treated with Matrix coils exhibited a more extensive area of organized thrombus when compared with the aneurysms treated with GDC (87% versus 75%, P=0.008, n=11). At 3 months, both Matrix and GDC-treated aneurysms demonstrated complete clot organization. Neck tissue thickness was higher in Matrix-treated aneurysms at 14 days and 3 months, but not at 6 months. No untoward parent artery stenosis was observed in aneurysms treated with Matrix during follow-up. The angiographic cross-sectional area of the Matrix-treated aneurysms was smaller than those treated with GDC at the 3 months. Conclusion-Matrix accelerated aneurysm fibrosis and neointima formation without parent artery stenosis. The Matrix system might prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.
引用
收藏
页码:2031 / 2037
页数:7
相关论文
共 44 条
[1]  
Abrahams JM, 2001, AM J NEURORADIOL, V22, P1410
[2]   Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils [J].
Bavinzski, G ;
Talazoglu, V ;
Killer, M ;
Richling, B ;
Gruber, A ;
Gross, CE ;
Plenk, H .
JOURNAL OF NEUROSURGERY, 1999, 91 (02) :284-293
[3]   Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding [J].
Byrne, JV ;
Sohn, NJ ;
Molyneux, AJ .
JOURNAL OF NEUROSURGERY, 1999, 90 (04) :656-663
[4]  
Castro E, 1999, AM J NEURORADIOL, V20, P549
[5]  
Dawson RC, 1996, AM J NEURORADIOL, V17, P853
[6]   Transforming growth factor β-coated platinum coils for endovascular treatment of aneurysms:: An animal study [J].
de Gast, AN ;
Altes, TA ;
Marx, WF ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
NEUROSURGERY, 2001, 49 (03) :690-694
[7]   Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: The preliminary university of Illinois at chicago experience [J].
Debrun, GM ;
Aletich, VA ;
Kehrli, P ;
Misra, M ;
Ausman, JI ;
Charbel, F .
NEUROSURGERY, 1998, 43 (06) :1281-1295
[8]   BIODEGRADABLE POLYMER SCAFFOLDS FOR TISSUE ENGINEERING [J].
FREED, LE ;
VUNJAKNOVAKOVIC, G ;
BIRON, RJ ;
EAGLES, DB ;
LESNOY, DC ;
BARLOW, SK ;
LANGER, R .
BIO-TECHNOLOGY, 1994, 12 (07) :689-693
[9]   ELECTROTHROMBOSIS OF SACCULAR ANEURYSMS VIA ENDOVASCULAR APPROACH .1. ELECTROCHEMICAL BASIS, TECHNIQUE, AND EXPERIMENTAL RESULTS [J].
GUGLIELMI, G ;
VINUELA, F ;
SEPETKA, I ;
MACELLARI, V .
JOURNAL OF NEUROSURGERY, 1991, 75 (01) :1-7
[10]   ELECTROTHROMBOSIS OF SACCULAR ANEURYSMS VIA ENDOVASCULAR APPROACH .2. PRELIMINARY CLINICAL-EXPERIENCE [J].
GUGLIELMI, G ;
VINUELA, F ;
DION, J ;
DUCKWILER, G .
JOURNAL OF NEUROSURGERY, 1991, 75 (01) :8-14