Characterization of metal-labelled peptides by matrix-assisted laser desorption/ionization mass spectrometry and tandem mass spectrometry

被引:13
作者
Gregorius, Barbara [1 ,2 ]
Schaumloeffel, Dirk [3 ]
Hildebrandt, Andreas [2 ]
Tholey, Andreas [1 ]
机构
[1] Univ Kiel, Inst Expt Med, Div Systemat Proteome Res, D-24105 Kiel, Germany
[2] Univ Saarland, Ctr Bioinformat, Jr Res Grp Protein Protein Interact & Computat Pr, D-66123 Saarbrucken, Germany
[3] Univ Pau & Pays Adour, CNRS, Lab Chim Analyt Bioinorgan & Environm, IPREM,UMR 5254, F-64053 Pau, France
关键词
COLLISION-INDUCED DISSOCIATION; DERIVATIZATION; QUANTITATION; COMPLEXES;
D O I
10.1002/rcm.4771
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine-or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b-and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in epsilon-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)-and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:3279 / 3289
页数:11
相关论文
共 23 条
  • [11] 2-7
  • [12] Peptide quantitation using primary amine selective metal chelation labels for mass spectrometry
    Kerr, Thomas J.
    McLean, John A.
    [J]. CHEMICAL COMMUNICATIONS, 2010, 46 (30) : 5479 - 5481
  • [13] Derivatization of phosphorylated peptides with S- and N-nucleophiles for enhanced ionization efficiency in matrix-assisted laser desorption/ionization mass spectrometry
    Klemm, C
    Schröder, S
    Glückmann, M
    Beyermann, M
    Krause, E
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (22) : 2697 - 2705
  • [14] A 2D reversed-phase x ion-pair reversed-phase HPLC-MALDI TOF/TOF-MS approach for shotgun proteome analysis
    Lasaosa, Maria
    Delmotte, Nathanael
    Huber, Christian G.
    Melchior, Katja
    Heinzle, Elmar
    Tholey, Andreas
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (04) : 1245 - 1256
  • [15] Electron-capture dissociation and collision-induced dissociation of lanthanide metal-ligand complexes and lanthanide metal-ligand complexes bound to phosphopeptides
    Mosely, Jackie A.
    Murray, Benjamin S.
    Parker, David
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (02) : 145 - 155
  • [16] Fragmentation behavior of metal-coded affinity tag (MeCAT)-labeled peptides
    Pieper, Stefan
    Beck, Sebastian
    Ahrends, Robert
    Scheler, Christian
    Linscheid, Michael W.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (13) : 2045 - 2052
  • [17] Progress and possible applications of miniaturised separation techniques and elemental mass spectrometry for quantitative, heteroatom-tagged proteomics
    Proefrock, Daniel
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (06) : 2383 - 2401
  • [18] Absolute Peptide Quantification by Lutetium Labeling and NanoHPLC-ICPMS with Isotope Dilution Analysis
    Rappel, Christina
    Schaumloeffel, Dirk
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (01) : 385 - 393
  • [19] Multiplexed protein quantitation in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents
    Ross, PL
    Huang, YLN
    Marchese, JN
    Williamson, B
    Parker, K
    Hattan, S
    Khainovski, N
    Pillai, S
    Dey, S
    Daniels, S
    Purkayastha, S
    Juhasz, P
    Martin, S
    Bartlet-Jones, M
    He, F
    Jacobson, A
    Pappin, DJ
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (12) : 1154 - 1169
  • [20] Schlosser A, 2000, J MASS SPECTROM, V35, P1382, DOI 10.1002/1096-9888(200012)35:12<1382::AID-JMS84>3.3.CO