Accuracy of computer-assisted navigation: significant augmentation by facial recognition software

被引:10
作者
Glicksman, Jordan T. [1 ]
Reger, Christine [1 ]
Parasher, Arjun K. [2 ]
Kennedy, David W. [1 ]
机构
[1] Univ Penn, Dept Otorhinolaryngol Head & Neck Surg, Philadelphia, PA 19104 USA
[2] Univ Penn, Leonard Davis Inst Hlth Econ, Philadelphia, PA 19104 USA
关键词
endoscopic sinus surgery; FESS; image guidance; navigation; photo-registration; ENDOSCOPIC SINUS SURGERY; IMAGE; REGISTRATION; METAANALYSIS; GUIDANCE;
D O I
10.1002/alr.21982
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Over the past 20 years, image guidance navigation has been used with increasing frequency as an adjunct during sinus and skull base surgery. These devices commonly utilize surface registration, where varying pressure of the registration probe and loss of contact with the face during the skin tracing process can lead to registration inaccuracies, and the number of registration points incorporated is necessarily limited. The aim of this study was to evaluate the use of novel facial recognition software for image guidance registration. Methods :Consecutive adults undergoing endoscopic sinus surgery (ESS) were prospectively studied. Patients underwent image guidance registration via both conventional surface registration and facial recognition software. The accuracy of both registration processes were measured at the head of the middle turbinate (MTH), middle turbinate axilla (MTA), anterior wall of sphenoid sinus (SS), and nasal tip (NT). Results: Forty-five patients were included in this investigation. Facial recognition was accurate to within a mean of 0.47 mm at the MTH, 0.33 mm at the MTA, 0.39 mm at the SS, and 0.36 mm at the NT. Facial recognition was more accurate than surface registration at the MTH by an average of 0.43 mm (p = 0.002), at the MTA by an average of 0.44 mm (p < 0.001), and at the SS by an average of 0.40 mm (p < 0.001). The integration of facial recognition software did not adversely affect registration time. Conclusion: In this prospective study, automated facial recognition software significantly improved the accuracy of image guidance registration when compared to conventional surface registration . (C) 2017 ARS-AAOA, LLC.
引用
收藏
页码:884 / 888
页数:5
相关论文
共 9 条
  • [1] American Academy of Otolaryngology-Head & Neck Surgery, 2014, POS STAT INTR US COM
  • [2] Ambulatory Sinus and Nasal Surgery in the United States: Demographics and Perioperative Outcomes
    Bhattacharyya, Neil
    [J]. LARYNGOSCOPE, 2010, 120 (03) : 635 - 638
  • [3] Image-Guided Surgery Influences Perioperative Morbidity from Endoscopic Sinus Surgery: A Systematic Review and Meta-Analysis
    Dalgorf, Dustin M.
    Sacks, Raymond
    Wormald, Peter-John
    Naidoo, Yuresh
    Panizza, Ben
    Uren, Brent
    Brown, Chris
    Curotta, John
    Snidvongs, Kornkiat
    Harvey, Richard J.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2013, 149 (01) : 17 - 29
  • [4] The role of registration in accurate surgical guidance
    Fitzpatrick, J. M.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H5) : 607 - 622
  • [5] PATIENT REGISTRATION USING PHOTOGRAMMETRIC SURFACE RECONSTRUCTION FROM SMARTPHONE IMAGERY
    Hellwich, O.
    Rose, A.
    Bien, T.
    Malolepszy, C.
    Mucha, D.
    Krueger, T.
    [J]. XXIII ISPRS CONGRESS, COMMISSION V, 2016, 41 (B5): : 829 - 833
  • [6] Endoscopic endonasal surgery for suprasellar meningiomas: experience with 75 patients Clinical article
    Koutourousiou, Maria
    Fernandez-Miranda, Juan C.
    Stefko, S. Tonya
    Wang, Eric W.
    Snyderman, Carl H.
    Gardner, Paul A.
    [J]. JOURNAL OF NEUROSURGERY, 2014, 120 (06) : 1326 - 1339
  • [7] Image-guided sinus surgery
    Pruliere-Escabasse, V.
    Coste, A.
    [J]. EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2010, 127 (01) : 33 - 39
  • [8] Computer or not? Use of image guidance during endoscopic sinus surgery for chronic rhinosinusitis at St Paul's Hospital, Vancouver, and meta-analysis
    Sunkaraneni, V. S.
    Yeh, D.
    Qian, H.
    Javer, A. R.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2013, 127 (04) : 368 - 377
  • [9] Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods
    Woerdeman, Peter A.
    Willems, Peter W. A.
    Noordmans, Herke J.
    Tulleken, Cornelis A. F.
    Van der Sprenkel, Jan Willem Berkelbach
    [J]. JOURNAL OF NEUROSURGERY, 2007, 106 (06) : 1012 - 1016