Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: Application to potentiometric monitoring of mercury ion(II)

被引:671
作者
Khani, Hadi [1 ]
Rofouei, Mohammad Kazem [1 ]
Arab, Pezhman [2 ]
Gupta, Vinod Kumar [3 ,4 ]
Vafaei, Zahra [1 ]
机构
[1] Tarbiat Moallem Univ, Fac Chem, Tehran, Iran
[2] Univ Tehran, Univ Coll Sci, Sch Chem, Tehran, Iran
[3] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[4] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
关键词
Mercury determination; Carbon paste electrode; Carbon nanotubes; Ionic liquid; MEMBRANE SENSORS; SPECTROMETRY; INJECTION; SAMPLES; MWCNTS; SYSTEM; RTILS;
D O I
10.1016/j.jhazmat.2010.07.039
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this article a super selectivity potentiometric methodology, using an ion-selective electrode, for determination of mercury ion(II) in aqueous solution was investigated. For modification of the electrode a room temperature ionic liquid, 1-n-butyl-3-methylimidazolium tetrafluoroborate (BMIM.BF4), was applied as a super conductive binder, and Multi-walled carbon nanotubes (MWCNTs) was used in the composition of the carbon paste to improve conductivity and transduction of chemical signal to electrical signal. Moreover, incorporation of 1-(2-ethoxyphenyl)-3-(3-nitrophenyl)triazene (ENTZ) as an ionophore to this composition caused to significantly enhanced selectivity toward Hg(II) ions over a wide concentration range of 1.0 x 10(-4) to 5.0 x 10(-9) M with a lower detection limit of 2.5 x 10(-9) M (0.5 ppb) and a Nernstian slope of 29.3 +/-(0.2) mV decade(-1) of Hg(II) activity. The electrode has a short response time (similar to 5s) and can be used for at least 55 days without any considerable divergence in potentials, and the working pH range was 2.0-4.3. Finally, the proposed electrode was successfully used as an indicator for potentiometric determination of Hg(II) in dental amalgam and water samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 43 条
[1]   A mercury(II) selective sensor based on N,N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples [J].
Abu-Shawish, Hazem M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :602-608
[2]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[3]   An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine) [J].
Bakhtiarzadeh, Fariba ;
Ab Ghani, Sulaiman .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 624 (1-2) :139-143
[4]   Carbon nanotubes: Synthesis, integration, and properties [J].
Dai, HJ .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (12) :1035-1044
[5]   Cold vapour atomic fluorescence spectrometry and gas chromatography-pyrolysis-atomic fluorescence spectrometry for routine determination of total and organometallic mercury in food samples [J].
Ebdon, L ;
Foulkes, ME ;
Le Roux, S ;
Muñoz-Olivas, R .
ANALYST, 2002, 127 (08) :1108-1114
[6]   Multi-walled carbon nanotubes (MWCNTs) and room temperature ionic liquids (RTILs) carbon paste Er(III) sensor based on a new derivative of dansyl chloride [J].
Faridbod, Farnoush ;
Ganjali, Mohammad Reza ;
Larijani, Bagher ;
Norouzi, Parviz .
ELECTROCHIMICA ACTA, 2009, 55 (01) :234-239
[7]   Room Temperature Ionic Liquids (RTILs) and Multiwalled Carbon Nanotubes (MWCNTs) as Modifiers for Improvement of Carbon Paste Ion Selective Electrode Response; A Comparison Study with PVC Membrane [J].
Ganjali, Mohammad Reza ;
Khoshsafar, Hamid ;
Faridbod, Farnoush ;
Shirzadmehr, Ali ;
Javanbakht, Mehran ;
Norouzi, Parviz .
ELECTROANALYSIS, 2009, 21 (19) :2175-2178
[8]   Neurotoxic effects of mercury on auditory cortex networks growing on microelectrode arrays: a preliminary analysis [J].
Gopal, KV .
NEUROTOXICOLOGY AND TERATOLOGY, 2003, 25 (01) :69-76
[9]   Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II) [J].
Gupta, V. K. ;
Singh, A. K. ;
Al Khayat, A. ;
Gupta, Barkha .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :81-90
[10]   Comparative studies of ONNO-based ligands as ionophores for palladium ion-selective membrane sensors [J].
Gupta, Vinod K. ;
Goyal, Rajendra N. ;
Sharma, Ram A. .
TALANTA, 2009, 78 (02) :484-490