The effect of a drainage layer on filtration performance of coalescing filters

被引:45
作者
Chang, Cheng [1 ]
Ji, Zhongli [1 ]
Zeng, Fanyong [1 ]
机构
[1] China Univ Petr, Coll Mech & Transportat Engn, Beijing Key Lab Proc Fluid Filtrat & Separat, Beijing 102249, Peoples R China
基金
中国国家自然科学基金;
关键词
Filtration; Coalescence; Liquid aerosols; Drainage layer; Liquid film; OIL-MIST FILTERS; PRESSURE-DROP; FIBROUS FILTERS; LIQUID AEROSOLS; VERTICAL FIBERS; DRAG FORCES; MOTION; MODEL;
D O I
10.1016/j.seppur.2016.06.006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of a drainage layer on the filtration performance of coalescing filters was evaluated experimentally. The "jump-and-channel" model was used to analyze saturation, pressure drop and efficiency of the filters with and without the drainage layer. The results showed that jump pressure drop dominated the wet pressure drop. The steady-state pressure drop was not proportional to filter saturation which was related primarily to the channel pressure drop. A liquid film was present between coalescing layer and drainage layer at steady state. The jump pressure drop was affected by the thickness of this liquid film. A thicker liquid film produced a higher jump pressure drop. When the drainage layer was assembled outside of the coalescing layer, pressure drop and penetration changed, and both saturation and efficiency increased significantly. A filter with a polyester drainage layer had the overall best performance. Furthermore, the dynamic thickness of the liquid film can be predicted using theoretical calculations, which allows qualitative analysis of the effect of the liquid film on filtration performance. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 30 条
[1]  
Agranovski IE, 1998, AICHE J, V44, P2775, DOI 10.1002/aic.690441218
[2]   Inclined wettable filter for mist purification [J].
Agranovski, IE ;
Myojo, T ;
Braddock, RD ;
Jarvis, D .
CHEMICAL ENGINEERING JOURNAL, 2002, 89 (1-3) :229-238
[3]  
Brown R. C., 1993, J AEROSOL SCI, DOI DOI 10.1016/0021-8502(95)90072-1
[4]   Filtration of liquid aerosols with a horizontal fibrous filter [J].
Charvet, A. ;
Gonthier, Y. ;
Bernis, A. ;
Gonze, E. .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2008, 86 (6A) :569-576
[5]   Experimental and modelled efficiencies during the filtration of a liquid aerosol with a fibrous medium [J].
Charvet, A. ;
Gonthier, Y. ;
Gonze, E. ;
Bernis, A. .
CHEMICAL ENGINEERING SCIENCE, 2010, 65 (05) :1875-1886
[6]   Clogging of fibre filters by submicron droplets.: Phenomena and influence of operating conditions [J].
Contal, P ;
Simao, J ;
Thomas, D ;
Frising, T ;
Callé, S ;
Appert-Collin, JC ;
Bémer, D .
JOURNAL OF AEROSOL SCIENCE, 2004, 35 (02) :263-278
[7]  
Davies CharlesNorman., 1973, Air filtration
[8]   Drag correlation for axial motion of drops on fibers [J].
Dawar, S. ;
Chase, G. G. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 60 (01) :6-13
[9]   Correlations for transverse motion of liquid drops on fibers [J].
Dawar, S. ;
Chase, G. G. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2010, 72 (03) :282-287
[10]   Clogging of fibrous filters by liquid aerosol particles:: Experimental and phenomenological modelling study [J].
Frising, T ;
Thomas, D ;
Bémer, D ;
Contal, P .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (10) :2751-2762