The Hounsfield value for cortical bone geometry in the proximal humerus-an in vitro study

被引:36
作者
Fat, Daren Lim [1 ]
Kennedy, Jim [1 ]
Galvin, Rose [1 ]
O'Brien, Fergal [1 ]
Mc Grath, Frank [1 ]
Mullett, Hannan [1 ]
机构
[1] Royal Coll Surgeons Ireland, Invest Carried Out Anat Lab, Dublin & Sports Surg Clin, Dublin 2, Ireland
关键词
Osteoporosis; Quantitative CT; Cortical bone geometry; Proximal humerus fracture; Image segmentation; SURGICAL NECK FRACTURES; COMPUTER-AIDED-DESIGN; MINERAL DENSITY; TOMOGRAPHY; FIXATION; HEAD; CT; STABILITY; THICKNESS; STRENGTH;
D O I
10.1007/s00256-011-1255-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fractures of the proximal humerus represent a major osteoporotic burden. Recent developments in CT imaging have emphasized the importance of cortical bone thickness distribution in the prevention and management of fragility fractures. We aimed to experimentally define the CT density of cortical bone in the proximal humerus for building cortical geometry maps. With ethical approval, we used ten fresh-frozen human proximal humeri. These were stripped of all soft tissue and high-resolution CT images were then taken. The humeral heads were then subsequently resected to allow access to the metaphyseal area. Using curettes, cancellous bone was removed down to hard cortical bone. Another set of CT images of the reamed specimen was then taken. Using CT imaging software and a CAD interface, we then compared cortical contours at different CT density thresholds to the reference inner cortical contour of our reamed specimens. Working with 3D model representations of these cortical maps, we were able to accurately make distance comparison analyses based on different CT thresholds. We could compute a single closest value at 700 HU. No difference was found in the HU-based contours generated along the 500-900 HU pixels (p = 1.000). The contours were significantly different from those generated at 300, 400, 1,000, and 1,100 HU. A Hounsfield range of 500-900 HU can accurately depict cortical bone geometry in the proximal humerus. Thresholding outside this range leads to statistically significant inaccuracies. Our results concur with a similar range reported in the literature for the proximal femur. Knowledge of regional variations in cortical bone thickness has direct implications for basic science studies on osteoporosis and its treatment, but is also important for the orthopedic surgeon since our decision for treatment options is often guided by local bone quality.
引用
收藏
页码:557 / 568
页数:12
相关论文
共 31 条
  • [11] Analysis of hip geometry by clinical CT for the assessment of hip fracture risk in elderly Japanese women
    Ito, Masako
    Wakao, Norimitsu
    Hida, Tetsuro
    Matsui, Yasumoto
    Abe, Yasue
    Aoyagi, Kiyoshi
    Uetani, Masataka
    Harada, Atsushi
    [J]. BONE, 2010, 46 (02) : 453 - 457
  • [12] A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data
    Kang, Y
    Engelke, K
    Kalender, WA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) : 586 - 598
  • [13] Surgical neck fractures of the proximal humerus: A laboratory evaluation of ten fixation techniques
    Koval, KJ
    Blair, B
    Takei, R
    Kummer, FJ
    Zuckerman, JD
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (05): : 778 - 783
  • [14] Effect of screw placement on fixation in the humeral head
    Liew, ASL
    Johnson, JA
    Patterson, SD
    King, GJW
    Chess, DG
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2000, 9 (05) : 423 - 426
  • [15] Remaining lifetime and absolute 10-year probabilities of osteoporotic fracture in Swiss men and women
    Lippuner, K.
    Johansson, H.
    Kanis, J. A.
    Rizzoli, R.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2009, 20 (07) : 1131 - 1140
  • [16] Relation between age, femoral neck cortical stability, and hip fracture risk
    Mayhew, PM
    Thomas, CD
    Clement, JG
    Loveridge, N
    Beck, TJ
    Bonfield, W
    Burgoyne, CJ
    Reeve, J
    [J]. LANCET, 2005, 366 (9480) : 129 - 135
  • [17] Three-dimensional finite element models based on in vivo microfocus computed tomography: Elimination of metal artefacts in a small laboratory animal model by registration with artefact-free reference images
    Muraru, L.
    Van Lierde, C.
    Naert, I.
    Vander Sloten, J.
    Jaecques, S. V. N.
    [J]. ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (11) : 1207 - 1210
  • [19] Innovations in the management of displaced proximal humerus fractures
    Nho, Shane J.
    Brophy, Robert H.
    Barker, Joseph U.
    Cornell, Charles N.
    MacGillivray, John D.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (01) : 12 - 26
  • [20] Three-dimensional osseous micro-architecture of the distal humerus: Implications for internal fixation of osteoporotic fracture
    Park, So Hyun
    Kim, Sung Jung
    Park, Byun Chul
    Suh, Kyung Jin
    Lee, Jee Young
    Park, Chun Woo
    Shin, Im Hee
    Jeon, In-Ho
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (02) : 244 - 250