The Hounsfield value for cortical bone geometry in the proximal humerus-an in vitro study

被引:36
作者
Fat, Daren Lim [1 ]
Kennedy, Jim [1 ]
Galvin, Rose [1 ]
O'Brien, Fergal [1 ]
Mc Grath, Frank [1 ]
Mullett, Hannan [1 ]
机构
[1] Royal Coll Surgeons Ireland, Invest Carried Out Anat Lab, Dublin & Sports Surg Clin, Dublin 2, Ireland
关键词
Osteoporosis; Quantitative CT; Cortical bone geometry; Proximal humerus fracture; Image segmentation; SURGICAL NECK FRACTURES; COMPUTER-AIDED-DESIGN; MINERAL DENSITY; TOMOGRAPHY; FIXATION; HEAD; CT; STABILITY; THICKNESS; STRENGTH;
D O I
10.1007/s00256-011-1255-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fractures of the proximal humerus represent a major osteoporotic burden. Recent developments in CT imaging have emphasized the importance of cortical bone thickness distribution in the prevention and management of fragility fractures. We aimed to experimentally define the CT density of cortical bone in the proximal humerus for building cortical geometry maps. With ethical approval, we used ten fresh-frozen human proximal humeri. These were stripped of all soft tissue and high-resolution CT images were then taken. The humeral heads were then subsequently resected to allow access to the metaphyseal area. Using curettes, cancellous bone was removed down to hard cortical bone. Another set of CT images of the reamed specimen was then taken. Using CT imaging software and a CAD interface, we then compared cortical contours at different CT density thresholds to the reference inner cortical contour of our reamed specimens. Working with 3D model representations of these cortical maps, we were able to accurately make distance comparison analyses based on different CT thresholds. We could compute a single closest value at 700 HU. No difference was found in the HU-based contours generated along the 500-900 HU pixels (p = 1.000). The contours were significantly different from those generated at 300, 400, 1,000, and 1,100 HU. A Hounsfield range of 500-900 HU can accurately depict cortical bone geometry in the proximal humerus. Thresholding outside this range leads to statistically significant inaccuracies. Our results concur with a similar range reported in the literature for the proximal femur. Knowledge of regional variations in cortical bone thickness has direct implications for basic science studies on osteoporosis and its treatment, but is also important for the orthopedic surgeon since our decision for treatment options is often guided by local bone quality.
引用
收藏
页码:557 / 568
页数:12
相关论文
共 31 条
  • [1] Determination of the Hounsfield value for CT-based design of custom femoral stems
    Aamodt, A
    Kvistad, KA
    Andersen, E
    Lund-Larsen, J
    Eine, J
    Benum, P
    Husby, OS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01): : 143 - 147
  • [2] Femoral anatomy, computed tomography and computer-aided design of prosthetic implants
    Adam, F
    Hammer, DS
    Pape, D
    Kohn, D
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 262 - 268
  • [3] The three-dimensional geometry of the proximal humerus - Implications for surgical technique and prosthetic design
    Boileau, P
    Walch, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05): : 857 - 865
  • [4] New QCT analysis approach shows the importance of fall orientation on femoral neck strength
    Carpenter, RD
    Beaupré, GS
    Lang, TF
    Orwoll, ES
    Carter, DR
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (09) : 1533 - 1542
  • [5] During sideways falls proximal femur fractures initiate in the superolateral cortex: Evidence from high-speed video of simulated fractures
    de Bakker, Peter M.
    Manske, Sarah L.
    Ebacher, Vincent
    Oxland, Thomas R.
    Cripton, Peter A.
    Guy, Pierre
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 1917 - 1925
  • [6] Garg A, 1985, Eng Med, V14, P89, DOI 10.1243/EMED_JOUR_1985_014_018_02
  • [7] Looking beyond bone mineral density Imaging assessment of bone quality
    Griffith, James F.
    Engelke, Klaus
    Genant, Harry K.
    [J]. SKELETAL BIOLOGY AND MEDICINE, 2010, 1192 : 45 - 56
  • [8] Accurate quantification of width and density of bone structures by computed tomography
    Hangartner, Thomas N.
    Short, David F.
    [J]. MEDICAL PHYSICS, 2007, 34 (10) : 3777 - 3784
  • [9] Where should implants be anchored in the humeral head?
    Hepp, P
    Lill, H
    Bail, H
    Korner, J
    Niederhagen, M
    Haas, NP
    Josten, C
    Duda, GN
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (415) : 139 - 147
  • [10] Hua J, 1993, P ISSCP AM ISL FL, P11