C1-C2 posterior screw fixation in atlantoaxial fractures revisited: technical update based on 127 cases

被引:12
作者
Buchmann, Niels [1 ,3 ]
Schweizer, Claudia [1 ]
Kirschke, Jan S. [2 ]
Rienmueller, Anna [1 ,6 ]
Gempt, Jens [1 ]
Ringel, Florian [1 ,5 ]
Meyer, Bernhard [1 ]
Ryang, Yu-Mi [1 ,4 ]
机构
[1] Tech Univ Munich, Dept Neurosurg, Klinikum Rechts Isar, Munich, Germany
[2] Tech Univ Munich, Dept Neuroradiol, Klinikum Rechts Isar, Munich, Germany
[3] Agatharied Hosp, Dept Orthoped & Traumatol, Norbert Kerkel Pl, D-83734 Hausham, Germany
[4] Helios Klinikum Berlin Buch, Dept Neurosurg, Berlin, Germany
[5] Johannes Gutenberg Univ Mainz, Univ Med, Dept Neurosurg, Mainz, Germany
[6] Univ Hosp Vienna, Orthoped Dept, Vienna, Austria
关键词
Atlantoaxial fracture; Posterior screw fixation; Accuracy; C1-C2; Odontoid fracture; C1 LATERAL MASS; ODONTOID FRACTURES; VERTEBRAL ARTERY; POLYAXIAL SCREW; C2; PEDICLE; ACCURACY; FUSION; PLACEMENT; OUTCOMES; NAVIGATION;
D O I
10.1007/s00586-019-06244-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction Posterior fusion of traumatic odontoid fractures by C1 lateral mass and C2 isthmic screws (modified Harms-Goel technique) is a viable alternative to transarticular screw fixation due to its universal applicability. This retrospective study reports on a series of 127 patients. Material and methods Our clinical database was screened for patients with fractures of the upper cervical spine incorporating a C2 fracture, operated on between 2007 and 2015. Patients were included if fused by internal fixation via C1 lateral mass screws, C2 isthmic screws in freehand technique under lateral fluoroscopy. Screw placement was controlled postoperatively by computed tomography and rated using the Gertzbein & Robbins classification. Surgery-related complications, consecutive treatment, revision surgeries and duration of surgeries were registered. Results In total, 127 patients were identified with altogether 572 screws. Correct screw positions of grade A and B according to Gertzbein & Robbins were achieved in a total of 539 (94.2%) screws (grade A: 453 (79.2%); grade B: 86 (15%)), grade C screw malpositions noted in 21 (3.7%), grade D in 10 (1.7%) and grade E in 2 (0.3%) screws. Vertebral artery canal breaches occurred in 29 screws (5.1%), with vertebral artery occlusion in 4 patients. Coiling of injured vertebral artery had to be performed in one patient. None of these patients suffered clinically apparent cerebrovascular complications. Revision surgery was performed in 8 patients (6%). Conclusion Posterior fixation of atlantoaxial fractures by C1 lateral mass and C2 isthmic screws with fluoroscopy without navigation is a safe and feasible method but not free of risk of vertebral artery injuries. Graphic abstract These slides can be retrieved under Electronic Supplementary Material.
引用
收藏
页码:1036 / 1042
页数:7
相关论文
共 36 条
[1]  
AbouMadawi A, 1997, J BONE JOINT SURG BR, V79B, P820
[2]   Neurological outcomes following iatrogenic vascular injury during posterior atlanto-axial instrumentation [J].
Akinduro, Oluwaseun O. ;
Baum, Griffin R. ;
Howard, Brian M. ;
Pradilla, Gustavo ;
Grossberg, Jonathan A. ;
Rodts, Gerald E., Jr. ;
Ahmad, Faiz U. .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2016, 150 :110-116
[3]   Risk Factors Associated With 30-day Readmissions After Instrumented Spine Surgery in 14,939 Patients 30-day readmissions after instrumented spine surgery [J].
Akins, Paul T. ;
Harris, Jessica ;
Alvarez, Julie L. ;
Chen, Yuexin ;
Paxton, Elizabeth W. ;
Bernbeck, Johannes ;
Guppy, Kern H. .
SPINE, 2015, 40 (13) :1022-1032
[4]   C1-C2 stabilization by harms arthrodesis: Indications, technique, complications and outcomes in a prospective 26-case series [J].
Bourdillon, P. ;
Perrin, G. ;
Lucas, F. ;
Debarge, R. ;
Barrey, C. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (02) :221-227
[5]   The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine [J].
Bredow, J. ;
Oppermann, J. ;
Kraus, B. ;
Schiller, P. ;
Schiffer, G. ;
Sobottke, R. ;
Eysel, P. ;
Koy, T. .
EUROPEAN SPINE JOURNAL, 2015, 24 (12) :2967-2976
[6]   The AOSpine North America Geriatric Odontoid Fracture Mortality Study A Retrospective Review of Mortality Outcomes for Operative Versus Nonoperative Treatment of 322 Patients With Long-Term Follow-Up [J].
Chapman, Jens ;
Smith, Justin S. ;
Kopjar, Branko ;
Vaccaro, Alexander R. ;
Arnold, Paul ;
Shaffrey, Christopher I. ;
Fehlings, Michael G. .
SPINE, 2013, 38 (13) :1098-1104
[7]   Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system [J].
Costa, Francesco ;
Ortolina, Alessandro ;
Attuati, Luca ;
Cardia, Andrea ;
Tomei, Massimo ;
Riva, Marco ;
Balzarini, Luca ;
Fornari, Maurizio .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) :128-133
[8]   Spinal navigation for posterior instrumentation of C1-2 instability using a mobile intraoperative CT scanner [J].
Czabanka, Marcus ;
Haemmerli, Julien ;
Hecht, Nils ;
Foehre, Bettina ;
Arden, Klaus ;
Liebig, Thomas ;
Woitzik, Johannes ;
Vajkoczy, Peter .
JOURNAL OF NEUROSURGERY-SPINE, 2017, 27 (03) :268-275
[9]   The Best Surgical Treatment for Type II Fractures of the Dens Is Still Controversial [J].
Denaro, Vincenzo ;
Papalia, Rocco ;
Di Martino, Alberto ;
Denaro, Luca ;
Maffulli, Nicola .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (03) :742-750
[10]   Atlantoaxial Fusion with Screw-Rod Constructs: Meta-Analysis and Review of Literature [J].
Elliott, Robert E. ;
Tanweer, Omar ;
Boah, Akwasi ;
Morsi, Amr ;
Ma, Tracy ;
Smith, Michael L. ;
Frempong-Boadu, Anthony .
WORLD NEUROSURGERY, 2014, 81 (02) :411-421