Kelvin Probe electrode for contactless potential measurement on concrete - Properties and corrosion profiling application

被引:15
|
作者
Saguees, Alberto A. [1 ]
Walsh, Michael T. [1 ]
机构
[1] Univ S Florida, Dept Civil & Environm Engn, Tampa, FL 33620 USA
关键词
Steel reinforced concrete; Polarization; Potential parameters; REINFORCED-CONCRETE; STEEL; CHLORIDE; DELAMINATION; POLARIZATION; RESISTANCE; LAYERS;
D O I
10.1016/j.corsci.2011.11.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The practical feasibility of Kelvin Probe measurement of potential of the concrete surface was demonstrated. The measurements require no contact between the reference element and the concrete. Potential readings when placing the probe on dry concrete were nearly instantaneous and highly stable, in contrast with considerable potential drift with a conventional wet-tip electrode. The probe output was only modestly sensitive to the reference element working distance. The shape and range of potential profiles measured with the probe on concrete with locally corroding reinforcement were consistent with those using a conventional wet-tip reference electrode, both identifying the anode location. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [1] Potential distribution measurement of metal electrode by Kelvin probe
    Tahara, Akira
    Kodama, Toshiaki
    Zairyo to Kankyo/ Corrosion Engineering, 1997, 46 (11): : 717 - 723
  • [2] Potential distribution measurement of galvanic corrosion by Kelvin probe
    Tahara, Akira
    Kodama, Toshiaki
    Zairyo to Kankyo/ Corrosion Engineering, 1998, 47 (06): : 391 - 395
  • [3] Macroscopic Kelvin probe for contactless corrosion assessment of structures buried in soil
    Sagues, A. A.
    Emmenegger, L. P.
    Velasquez, E. A. Paz
    Ruth, W. C.
    2016 IEEE SENSORS, 2016,
  • [4] Potentiometric measurement with a Kelvin probe: Contactless measurement of chloride ions in aqueous electrolyte
    Abbas, Y.
    Zhu, X.
    de Boer, H. L.
    Tanvir, N. B.
    Olthuis, W.
    van den Berg, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 1126 - 1132
  • [5] Potential distribution measurement in galvanic corrosion of Zn/Fe couple by means of Kelvin probe
    Tahara, A
    Kodama, T
    CORROSION SCIENCE, 2000, 42 (04) : 655 - 673
  • [6] Kelvin Probe Array for Rapid Survey of Reinforced Concrete Corrosion
    Emmenegger, Leonidas P.
    Sagues, Alberto A.
    ACI MATERIALS JOURNAL, 2020, 117 (02) : 135 - 144
  • [7] Simultaneous measurement of corrosion potential and hydrogen penetration using double-head scanning Kelvin probe
    Sugae, Kiyonobu
    Otsuka, Yasuyo
    Kamimura, Takayuki
    ELECTROCHEMISTRY COMMUNICATIONS, 2024, 163
  • [8] Kelvin probe measurement of corrosion potential of low-alloyed steels and the thickness of electrolyte layer during cyclic corrosion condition
    Nippon Steel Corp, Japan
    Zairyo to Kankyo/ Corrosion Engineering, 1998, 47 (06): : 406 - 410
  • [9] Measurement of Surface Potential and Adhesion with Kelvin Probe Force Microscopy
    Zhang, Hao
    Hussain, Danish
    Meng, Xianghe
    Song, Jianmin
    Xie, Hui
    2016 INTERNATIONAL CONFERENCE ON MANIPULATION, AUTOMATION AND ROBOTICS AT SMALL SCALES (MARSS), 2016,
  • [10] Potential Characterization of Interconnect Corrosion by Kelvin Probe and Electrostatic Force Microscopies
    Kodera, Masako
    Yoshimizu, Yasuhito
    Uchida, Kanae
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (04)