Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7

被引:122
作者
Lin, Yueh-Hui [1 ,2 ]
Chen, Sz-Hau [1 ]
Chuang, Yao-Chen [1 ]
Lu, Yi-Chen [1 ]
Shen, Thomas Y. [2 ]
Chang, C. Allen [1 ]
Lin, Chih-Sheng [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu 30068, Taiwan
[2] Apex Biotechnol Corp, Hsinchu 30078, Taiwan
关键词
Escherichia coli O157 : H7; screen-printed carbon electrode; immunosensor; electrochemistry; nanoparticles;
D O I
10.1016/j.bios.2008.02.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A disposable amperometric immunosensing strip was fabricated for rapid detection of Escherichia coli O157:H7. The method uses an indirect sandwich enzyme-linked immunoassay with double antibodies. Screen-printed carbon electrodes (SPCEs) were framed by commercial silver and carbon inks. For electrochemical characterization the carbon electrodes were coupled with the first E. coli O157:H7-specific antibody, E. coli O157:H7 intact cells and the second E. coli O157:H7-specific antibody conjugated with horseradish peroxidase (HRP). Hydrogen peroxide and ferrocenedicarboxylic acid (FeDC) were used as the substrate for HRP and mediator, respectively, at a potential +300 mV vs. counter/reference electrode. The response current (RC) of the immunosensing strips could be amplified significantly by 13-nm diameter Au nanoparticles (AuNPs) attached to the working electrode. The results show that the combined effects of AuNPs and FeDC enhanced RC by 13.1-fold. The SPCE immunosensing strips were used to detect E. coli O157:H7 specifically. Concentrations of E. coli O157:H7 from 10(2) to 10(7) CFU/ml could be detected. The detection limit was approximately 6 CFU/strip in PBS buffer and 50 CFU/strip in milk. The SPCE modified with AuNPs and FeDC has the potential for further applications and provides the basis for incorporating the method into an integrated system for rapid pathogen detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1832 / 1837
页数:6
相关论文
共 33 条
[1]   Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7 [J].
Abdel-Hamid, I ;
Ivnitski, D ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) :309-316
[2]   Electrochemical sensors [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3285-3298
[3]   Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads [J].
Boyaci, IH ;
Aguilar, ZP ;
Hossain, M ;
Halsall, HB ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) :1234-1241
[4]   Electrochemical genosensors for biomedical applications based on gold nanoparticles [J].
Castaneda, M. T. ;
Merkoci, A. ;
Pumera, M. ;
Alegret, S. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :1961-1967
[5]   Detection of pathogenic bacteria in food samples using highly-dispersed carbon particles [J].
Chemburu, S ;
Wilkins, E ;
Abdel-Hamid, I .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :491-499
[6]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[7]   Some recent designs and developments of screen-printed carbon electrochemical sensors/biosensors for biomedical, environmental, and industrial analyses [J].
Hart, JP ;
Crew, A ;
Crouch, E ;
Honeychurch, KC ;
Pemberton, RM .
ANALYTICAL LETTERS, 2004, 37 (05) :789-830
[8]   Liposome-based microcapillary immunosensor for detection of Escherichia coli O157:H7 [J].
Ho, JAA ;
Hsu, HW ;
Huang, MR .
ANALYTICAL BIOCHEMISTRY, 2004, 330 (02) :342-349
[9]  
JOHNSON JL, 1995, J FOOD PROTECT, V58, P597, DOI 10.4315/0362-028X-58.6.597
[10]  
Kim Seong-Hee, 2005, J Vet Sci, V6, P41