CT effective dose per dose length product using ICRP 103 weighting factors

被引:133
作者
Huda, Walter [2 ]
Magill, Dennise [2 ]
He, Wenjun [1 ]
机构
[1] Clemson Univ, Dept Bioengn, Clemson MUSC Bioengn Program, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
CT; effective dose; dose length product; TUBE CURRENT MODULATION; RADIOLOGY; SIZE;
D O I
10.1118/1.3544350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To generate effective dose per unit dose length product (E/DLP) conversion factors incorporating ICRP Publication 103 tissue weighting factors. Methods: Effective doses for CT examinations were obtained using the IMPACT Dosimetry Calculator using all 23 dose data sets that are offered by this spreadsheet. CT examinations were simulated for scans performed along the patient long axis for each dosimetry data set using a 4 cm beam width ranging from the upper thighs to top of the head. Five basic body regions (head, neck, chest, abdomen, and pelvis), as well as combinations of the regions (head/neck, chest/abdomen, abdomen/pelvis, and chest/abdomen/pelvis) and whole body CT scans were investigated. Correction factors were generated that can be applied to convert E/DLP conversion factors based on ICRP 60 data to conversion factors that are valid for ICRP 103 data (i.e., E-103/E-60). Results: Use of ICRP 103 weighting factors increase effective doses for head scans by similar to 11%, for chest scans by similar to 20%, and decrease effective doses for pelvis scans by similar to 25%. Current E/DLP conversion factors are estimated to be 2.4 mu Sv/mGy cm for head CT examinations and range between 14 and 20 mu Sv/mGy cm for body CT examinations. Conclusions: Factors that enable patient CT doses to be adjusted to account for ICRP 103 tissue weighting factors are provided, which result in E/DLP factors that were increased in head and chest CT, reduced in pelvis CT, and showed no marked change in neck and abdomen CT. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3544350]
引用
收藏
页码:1261 / 1265
页数:5
相关论文
共 27 条
[1]  
*AAPM, 2008, 96 AAPM, P96
[2]  
[Anonymous], 2009, National Council on Radiation Protection and Measurement report No. 160: Ionizing radiation exposure of the population of the United States
[3]  
[Anonymous], 2003, Ann ICRP, V33, P1, DOI [10.1016/S0146-6453(03)00024-1, DOI 10.1016/S0146-6453(03)00024-1]
[4]   The use of effective dose for medical procedures is inappropriate [J].
Borras, Caridad ;
Huda, Walter ;
Orton, Colin G. .
MEDICAL PHYSICS, 2010, 37 (07) :3497-3500
[5]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[6]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247
[7]   X-RAY TUBE CURRENT MODULATION AND PATIENT DOSES IN CHEST CT [J].
He, Wenjun ;
Huda, Walter ;
Magill, Dennise ;
Tavrides, Emily ;
Yao, Hai .
RADIATION PROTECTION DOSIMETRY, 2011, 143 (01) :81-87
[8]  
HUDA M, 2006, RSNA CATEGORICAL COU, P29
[9]   Converting dose-length product to effective dose at CT [J].
Huda, Walter ;
Ogden, Kent M. ;
Khorasani, Mohammad R. .
RADIOLOGY, 2008, 248 (03) :995-1003
[10]   Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They? [J].
Huda, Walter ;
Mettler, Fred A. .
RADIOLOGY, 2011, 258 (01) :236-242