Measurement of diaphragm loading during pressure support ventilation

被引:17
作者
Fauroux, B
Hart, N
Luo, YM
MacNeill, S
Moxham, J
Lofaso, F
Polkey, MI
机构
[1] Royal Brompton Hosp, Resp Muscle Lab, London SW3 6NP, England
[2] Armand Trousseau Hosp, Assistance Publ Hop Paris, Dept Paediat Pulm, Paris, France
[3] Armand Trousseau Hosp, Assistance Publ Hop Paris, INSERM, Res Unit E213, Paris, France
[4] Raymond Poincare Hosp, Assistance Publ Hop Paris, Dept Physiol, Garches, France
关键词
diaphragm; pressure time product; oesophageal electromyography; pressure-support ventilation; inspiratory pressure support ventilation diaphragmatic electromyography;
D O I
10.1007/s00134-003-1941-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. The diaphragmatic pressure-time product (PTPdi) has been used to quantify the loading and unloading of the diaphragm. The validity of the relationship between PTPdi and diaphragm electrical activity (EMGdi) during pressure-support ventilation (PSV) is unclear. We examined this relationship. Design and setting. Physiological study in a physiology laboratory. Subjects. Six healthy adults. Interventions. Spontaneous breathing (SB) and two levels of PSV (6 and 12 cmH(2)O), breathing room air and incremental concentrations of carbon dioxide, sufficient to achieve an EMGdi signal of approximately 200% of baseline value. Measurements and results. We measured the electrical (EMGdi) and mechanical (PTPdi) activity of the diaphragm using oesophageal electrode and oesophageal and gastric balloon catheters. The relationship between EMGdi and PTPdi during SB was linear in five subjects and curvilinear in one. However, with PSV 12 cmH(2)O we observed that the relationship between EMGdi and PTPdi was 'left shifted'; specifically, for any given level of EMGdi the PTPdi was smaller with PSV 12 cmH(2)O than during SB. However, when PTPdi was converted to power (the product of pressure and flow) the tendency to left shift was largely reversed. Conclusions. We conclude that when assessing of diaphragm unloading during PSV flow measurements are required. Where flow is constant, PTPdi is a valid measure of diaphragm unloading, but if not these data may be used to make an appropriate correction.
引用
收藏
页码:1960 / 1966
页数:7
相关论文
共 24 条
[1]   ELECTROMYOGRAPHY OF THE DIAPHRAGM IN MAN AND TRANSDIAPHRAGMATIC PRESSURE [J].
AGOSTONI, E ;
SANTAMBROGIO, G ;
CARRASCO, HD .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (06) :1093-1097
[2]   Electrical activity of the diaphragm during pressure support ventilation in acute respiratory failure [J].
Beck, J ;
Gottfried, SB ;
Navalesi, P ;
Skrobik, Y ;
Comtois, N ;
Rossini, M ;
Sinderby, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (03) :419-424
[3]   THE RELATION BETWEEN FORCE, VELOCITY AND INTEGRATED ELECTRICAL ACTIVITY IN HUMAN MUSCLES [J].
BIGLAND, B ;
LIPPOLD, OCJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1954, 123 (01) :214-224
[4]   Increased initial flow rate reduces inspiratory work of breathing during pressure support ventilation in patients with exacerbation of chronic obstructive pulmonary disease [J].
Bonmarchand, G ;
Chevron, V ;
Chopin, C ;
Jusserand, D ;
Girault, C ;
Moritz, F ;
Leroy, J ;
Pasquis, P .
INTENSIVE CARE MEDICINE, 1996, 22 (11) :1147-1154
[5]   IMPROVED EFFICACY OF SPONTANEOUS BREATHING WITH INSPIRATORY PRESSURE SUPPORT [J].
BROCHARD, L ;
PLUSKWA, F ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (02) :411-415
[6]  
COLLET PW, 1984, J APPL PHYSIOL, V58, P1263
[7]   PRESSURE-TIME PRODUCT, WORK RATE, AND ENDURANCE DURING RESISTIVE BREATHING IN HUMANS [J].
DODD, DS ;
KELLY, S ;
COLLETT, PW ;
ENGEL, LA .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (04) :1397-1404
[8]   In vivo physiologic comparison of two ventilators used for domiciliary ventilation in children with cystic fibrosis [J].
Fauroux, B ;
Pigeot, J ;
Polkey, MI ;
Isabey, D ;
Clément, A ;
Lofaso, F .
CRITICAL CARE MEDICINE, 2001, 29 (11) :2097-2105
[9]   MECHANICS OF HUMAN DIAPHRAGM DURING VOLUNTARY CONTRACTION - DYNAMICS [J].
GOLDMAN, MD ;
GRASSINO, A ;
MEAD, J ;
SEARS, TA .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (06) :840-848
[10]   MECHANICS OF HUMAN DIAPHRAGM DURING VOLUNTARY CONTRACTION - STATICS [J].
GRASSINO, A ;
GOLDMAN, MD ;
MEAD, J ;
SEARS, TA .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (06) :829-839