Simple and highly sensitive determination of morphine in rat plasma by liquid chromatography with fluorescence detection

被引:23
作者
Hara, S [1 ]
Mochinaga, S [1 ]
Fukuzawa, M [1 ]
Ono, N [1 ]
Kuroda, T [1 ]
机构
[1] Fukuoka Univ, Fac Pharmaceut Sci, Jonan Ku, Fukuoka 8140180, Japan
关键词
morphine; benzylamine; fluorescence detection; liquid chromatography;
D O I
10.1016/S0003-2670(99)00108-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive liquid chromatographic method for the determination of morphine in rat plasma is described. This method is based on the selective reaction of morphine with benzylamine in neutral media (borate buffer, pH 7.0) in the presence of potassium hexacyanoferrate(III) to give a highly fluorescent derivative. The derivative was determined by isocratic elution using acetonitrile-25 mM phosphate buffer (pH 8.5) on a YMC-Pack polymer C-18 reversed-phase column. The detection Limit (signal-to-noise ratio=3) for morphine was 5.7 pg (20 fmol) in a 20 mu l injection volume (1.4 ng ml(-1) plasma), which allowed precise determination of morphine in plasma at very low concentrations with a quite small amount of plasma (50 mu l) without prior extraction. The calibration graph was linear from 3 ng ml(-1) to 1 mu g ml(-1) in plasma. The method was applied to monitoring the drug concentrations in rat plasma samples obtained after an intravenous administration of morphine hydrochloride (5.0 mg kg(-1)). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 23 条
[1]   DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1987, 112 (04) :397-406
[2]   MORPHINE AND MORPHINE GLUCURONIDES IN SERUM OF HEROIN CONSUMERS AND IN HEROIN-RELATED DEATHS DETERMINED BY HPLC WITH NATIVE FLUORESCENCE DETECTION [J].
ADERJAN, R ;
HOFMANN, S ;
SCHMITT, G ;
SKOPP, G .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (03) :163-168
[3]   Morphine determination by HPLC with improved chemiluminescence detection using a conventional silica based column [J].
Amiott, E ;
Andrews, ARJ .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (02) :311-325
[4]   DETERMINATION OF MORPHINE AND 6-ACETYLMORPHINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BARRETT, DA ;
SHAW, PN ;
DAVIS, SS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 566 (01) :135-145
[5]   ION-PAIR EXTRACTION AND LIQUID-CHROMATOGRAPHIC ANALYSIS OF MORPHINE IN RAT-BRAIN AND PLASMA [J].
BORG, PJ ;
SITARAM, BR ;
TAYLOR, DA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 621 (02) :165-172
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, MORPHINE-6-GLUCURONIDE AND CODEINE IN BIOLOGICAL SAMPLES USING MULTIWAVELENGTH FORWARD OPTICAL-DETECTION [J].
CHARI, G ;
GULATI, A ;
BHAT, R ;
TEBBETT, IR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2) :263-270
[7]   SIMULTANEOUS DETERMINATION OF MORPHINE AND CODEINE IN BLOOD AND BILE USING DUAL ULTRAVIOLET AND FLUORESCENCE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CRUMP, KL ;
MCINTYRE, IM ;
DRUMMER, OH .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (04) :208-212
[8]   PHARMACOKINETICS AND PHARMACODYNAMICS OF MORPHINE-3-GLUCURONIDE IN RATS AND ITS INFLUENCE ON THE ANTINOCICEPTIVE EFFECT OF MORPHINE [J].
EKBLOM, M ;
GARDMARK, M ;
HAMMARLUNDUDENAES, M .
BIOPHARMACEUTICS & DRUG DISPOSITION, 1993, 14 (01) :1-11
[9]  
Emara S, 1998, BIOMED CHROMATOGR, V12, P15, DOI 10.1002/(SICI)1099-0801(199801/02)12:1<15::AID-BMC713>3.0.CO
[10]  
2-R