A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation

被引:18
作者
Kempfert, Joerg [3 ]
Rastan, Ardawan J. [3 ]
Schuler, Gerhard [2 ]
Linke, Axel [2 ]
Holzhey, David [3 ]
van Linden, Arnaud [3 ]
Mohr, Friedrich-W. [3 ]
Walther, Thomas [1 ]
机构
[1] Kerckhoff Clin Bad Nauheim, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
[2] Univ Leipzig, Heartctr, Dept Cardiol, Leipzig, Germany
[3] Univ Leipzig, Heartctr, Dept Cardiac Surg, Leipzig, Germany
关键词
Aortic valve implantation; Minimally invasive; Trans-apical; IN-VALVE;
D O I
10.1016/j.ejcts.2011.03.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN (TM) prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN (TM) valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a second prosthesis within the first one. Results of this 'bailout' maneuver have not been reported yet. Methods: Of 305 TA-AVI procedures, 15 patients required a second prosthesis due to dysfunctional leaflets (n = 6), low position (n = 7), or VSD (n = 2). Mean age was 82.5 +/- 1.3 years, mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 45.5 +/- 5.4, and Society of Thoracic Surgeons (STS) Score was 13.5 +/- 1.5. Results: All second SAPIEN (TM) valves could be implanted successfully within the first one. The second prosthesis solved leaflet dysfunction, sealed the VSD (lower position of the second prosthesis), or corrected the initial misplacement (higher position of the second prosthesis) in all patients. Within 30 days, four patients died (low cardiac output n = 3, all with preoperative ejection fraction (EF) < 35%; intestinal ischemia n = 1). Intra-operative echocardiogram and angiogram revealed mild paravalvular leak in three and none/trace in 12 patients. Transvalvular gradients were low despite the implantation of the second valve (P(max)/mean 13.7 +/- 4.3/6.4 +/- 2.0). Conclusion: Placement of a second SAPIEN (TM) valve is a valuable 'bailout' technique in case of VSD, dysfunctional leaflets, or too low placement of the first prosthesis. The technique leads to an excellent functional result with low transvalvular gradients. The simple, straight, tubular stent design of the SAPIEN (TM) prosthesis may be the ideal design for such valve-in-valve procedures. (C) 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 11 条
[1]   Minimally Invasive Off-Pump Aortic Valve Implantation: The Surgical Safety Net [J].
Kempfert, Joerg ;
Walther, Thomas ;
Borger, Michael A. ;
Lehmann, Sven ;
Blumenstein, Johannes ;
Fassl, Jens ;
Schuler, Gerhard ;
Mohr, Friedrich-Wilhelm .
ANNALS OF THORACIC SURGERY, 2008, 86 (05) :1665-1668
[2]   Dyna-CT During Minimally Invasive Off-Pump Transapical Aortic Valve Implantation [J].
Kempfert, Joerg ;
Falk, Volkmar ;
Schuler, Gerhard ;
Linke, Axel ;
Merk, Denis ;
Mohr, Friedrich W. ;
Walther, Thomas .
ANNALS OF THORACIC SURGERY, 2009, 88 (06) :2041-2041
[3]  
PASUPATI S, 2010, HEART LUNG CIRC
[4]   Implantation of Two Self-Expanding Aortic Bioprosthetic Valves During the Same Procedure-Insights into Valve-in-Valve Implantation ("Russian Doll Concept") [J].
Piazza, Nicolo ;
Schultz, Carl ;
de Jaegere, Peter P. T. ;
Serruys, Patrick W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (04) :530-539
[5]  
Piazza Nicolo, 2008, EuroIntervention, V4, P242, DOI 10.4244/EIJV4I2A43
[6]   "Valve-in-Valve" for the Treatment of Paravalvular Leaks Following Transcatheter Aortic Valve Implantation [J].
Rodes-Cabau, Josep ;
Dumont, Eric ;
Doyle, Daniel .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (07) :1116-1119
[7]   First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up [J].
Ruiz, Carlos E. ;
Laborde, Jean C. ;
Condado, Jose F. ;
Chiam, Paul T. L. ;
Condado, Jose A. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :143-148
[8]   Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve [J].
Thomas, Martyn ;
Schymik, Gerhard ;
Walther, Thomas ;
Himbert, Dominique ;
Lefevre, Thierry ;
Treede, Hendrik ;
Eggebrecht, Holger ;
Rubino, Paolo ;
Michev, Iassen ;
Lange, Ruediger ;
Anderson, William N. ;
Wendler, Olaf .
CIRCULATION, 2010, 122 (01) :62-U130
[9]   Six-month results of a repositionable and retrievable pericardial valve for transcatheter aortic valve replacement: The Direct Flow Medical aortic valve [J].
Treede, Hendrik ;
Tuebler, Thilo ;
Reichenspurner, Hermann ;
Grube, Eberhard ;
Pascotto, Andrea ;
Franzen, Olaf ;
Mueller, Ralf ;
Low, Reginald ;
Bolling, Steven F. ;
Meinertz, Thomas ;
Schofer, Joachim .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (04) :897-903
[10]   Transapical aortic valve implantation in 100 consecutive patients: comparison to propensity-matched conventional aortic valve replacement [J].
Walther, Thomas ;
Schuler, Gerhard ;
Borger, Michael A. ;
Kempfert, Joerg ;
Seeburger, Joerg ;
Rueckert, Yvonne ;
Ender, Joerg ;
Linke, Axel ;
Scholz, Markus ;
Falk, Volkmar ;
Mohr, Friedrich W. .
EUROPEAN HEART JOURNAL, 2010, 31 (11) :1398-1403