A Study on Factors Influencing Toughness of Basic Flux-Cored Weld of Modified 9Cr-1Mo Steel

被引:10
作者
Arivazhagan, B. [1 ]
Kamaraj, M. [1 ]
机构
[1] Indian Inst Technol, Dept Met & Mat Engn, Madras 600036, Tamil Nadu, India
关键词
basicity; delta-ferrite; remelting; toughness; MECHANICAL-PROPERTIES; MICROSTRUCTURAL DEVELOPMENT; EVOLUTION;
D O I
10.1007/s11665-010-9757-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Flux-cored arc welding (FCAW) is relatively a new process for joining of modified 9Cr-1Mo (P91) steel. In this study, effect of shielding gas composition, inclusion content, gas tungsten-arc welding (GTAW) surface remelting, and postweld heat treatment (PWHT) on toughness were investigated. The high amount of silicon resulted in the formation of delta-ferrite in basic flux-cored weld. A mixture of 80% argon + 20% (80A) carbon dioxide shielding gas during welding resulted in the required toughness of 47 J at room temperature. The 95% argon + 5% carbon dioxide (95A) gas-shielded welds have lower toughness due to higher amount of delta-ferrite (4%) than 80% argon + 20% carbon dioxide welds (2%). In essence, most desirable shielding gas medium to achieve optimum toughness was 80% argon + 20% carbon dioxide in basic flux-cored arc welding.
引用
收藏
页码:1188 / 1195
页数:8
相关论文
共 18 条
[1]   Effect of TIG arc surface melting process on weld metal toughness of modified 9Cr-1Mo (P91) steel [J].
Arivazhagan, B. ;
Sundaresan, S. ;
Kamaraj, A. .
MATERIALS LETTERS, 2008, 62 (17-18) :2817-2820
[2]  
BARNES A, 1995, 5091995 TWI
[3]  
Barnes AM, 1998, MICRO HIGH TEMP MAT, P339
[4]  
Bergquist EL., 1999, Svetsaren, V54, P22
[5]  
Cerjak H, 1998, MICRO HIGH TEMP MAT, P323
[6]  
CUNNINGHAM GW, 1983, MICROSTRUCTURAL STAB, P3
[7]  
DITTRICH S, 1994, NAT WELD SEM IIW JAM
[8]  
FRENCH IE, 1995, WELD J, V74, pS197
[9]   MICROSTRUCTURAL EVOLUTION OF MODIFIED 9CR-1MO STEEL [J].
JONES, WB ;
HILLS, CR ;
POLONIS, DH .
METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1991, 22 (05) :1049-1058
[10]  
KOU S, 2003, WELDING METALLURGY, P54