The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips

被引:6
|
作者
Kristoffersson, Emelie [1 ]
Otten, Volker [1 ]
Crnalic, Sead [1 ]
机构
[1] Umea Univ, Dept Surg & Perioperat Sci Orthopaed, S-90185 Umea, Sweden
关键词
Digital templating; Dysplasia; Cementless total hip arthroplasty; Accuracy; DEVELOPMENTAL DYSPLASIA; REPLACEMENT; JOINT;
D O I
10.1186/s12891-021-04793-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) is a complex procedure due to associated anatomical abnormalities. We studied the extent to which preoperative digital templating is reliable when performing cementless THA in patients with DDH. Methods We templated and compared the pre- and postoperative sizes of the acetabular and femoral components and the center of rotation (COR), and analysed the postoperative cup coverage, leg length discrepancy (LLD), and stem alignment in 50 patients (56 hips) with DDH treated with THA. Results The implant size exactly matched the template size in 42.9% of cases for the acetabular component and in 38.2% of cases for the femoral component, whereas the templated +/- 1 size was used in 80.4 and 81.8% of cases for the acetabular and femoral components, respectively. There were no statistically significant differences between templated and used component sizes among different DDH severity levels (acetabular cup: p = 0.30 under the Crowe classification and p = 0.94 under the Hartofilakidis classification; femoral stem: p = 0.98 and p = 0.74, respectively). There were no statistically significant differences between the planned and postoperative COR (p = 0.14 horizontally and p = 0.52 vertically). The median postoperative LLD was 7 (range 0-37) mm. Conclusion Digital preoperative templating is reliable in the planning of cementless THA in patients with DDH.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Cementless Total Hip Arthroplasty in Octogenarians
    Stihsen, Christoph
    Springer, Bernhard
    Nemecek, Elena
    Olischar, Boris
    Kaider, Alexandra
    Windhager, Reinhard
    Kubista, Bernd
    JOURNAL OF ARTHROPLASTY, 2017, 32 (06) : 1923 - 1929
  • [32] Total hip arthroplasty for dysplastic coxarthrosis using a cementless Wagner Cone stem
    Solarino, Giuseppe
    Vicenti, Giovanni
    Piazzolla, Andrea
    Maruccia, Francesco
    Notarnicola, Angela
    Moretti, Biagio
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 22 (01)
  • [33] Total hip arthroplasty for dysplastic coxarthrosis using a cementless Wagner Cone stem
    Giuseppe Solarino
    Giovanni Vicenti
    Andrea Piazzolla
    Francesco Maruccia
    Angela Notarnicola
    Biagio Moretti
    Journal of Orthopaedics and Traumatology, 2021, 22
  • [34] Cementless Modular Total Hip Arthroplasty with Subtrochanteric Shortening Osteotomy for Hips with Developmental Dysplasia
    Takao, Masaki
    Ohzono, Kenji
    Nishii, Takashi
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (06) : 548 - 555
  • [35] Digital templating in total hip arthroplasty in the NHS: ‘computer says no…’
    Luckshmana Jeyaseelan
    Jonathan Ward
    Kyriacos Eleftheriou
    J. Cobb
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 397 - 399
  • [36] Validity of Digital Templating in Total Hip Arthroplasty: Impact of Stem Design and Planner's Experience
    Jung, S.
    Neuerburg, C.
    Kappe, T.
    Wernerus, D.
    Reichel, H.
    Bieger, R.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2012, 150 (04): : 404 - 408
  • [37] Dysplastic Hips That Are Too Late for Periacetabular Osteotomy Are Not Too Early for Total Hip Arthroplasty
    Treu, Emily A.
    Sato, Eleanor H.
    Omotowa, Olaoluwa M.
    Heaton, Tanner B.
    Erickson, Jill A.
    Blackburn, Brenna E.
    Peters, Christopher L.
    Anderson, Lucas A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S131 - S137
  • [38] Cementless total hip arthroplasty in patients with severely dysplastic hips and a previous Schanz osteotomy of the femur Techniques, pitfalls, and long-term outcome
    Eskelinen, Antti
    Remes, Ville
    Ylinen, Pekka
    Helenius, Ilkka
    Tallroth, Kaj
    Paavilainen, Timo
    ACTA ORTHOPAEDICA, 2009, 80 (03) : 263 - 269
  • [39] Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system
    Bertz, Ari
    Indrekvam, Kari
    Ahmed, Mohamed
    Englund, Erling
    Sayed-Noor, Arkan S.
    SKELETAL RADIOLOGY, 2012, 41 (10) : 1245 - 1249
  • [40] Accuracy of a New Digital Templating Method for Total Hip Arthroplasty Using Picture Archiving and Communication System (PACS) and iPhone Technology: Comparison With Acetate Templating on Digital Radiography
    Pongkunakorn, Anuwat
    Aksornthung, Chayanut
    Sritumpinit, Nithipat
    JOURNAL OF ARTHROPLASTY, 2021, 36 (06) : 2204 - 2210