A Method to Examine the Impact of Grid Connection of the DFIGs on Power System Electromechanical Oscillation Modes

被引:86
作者
Du, Wenjuan [1 ]
Bi, Jingtian [1 ]
Cao, Jun [1 ]
Wang, H. F. [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst New Ener, Beijing, Peoples R China
关键词
Electromechanical oscillation modes; power system small-signal angular stability; DFIG; damping torque analysis (DTA); STATIC VAR COMPENSATORS; WIND; STABILITY; GENERATION; MACHINE;
D O I
10.1109/TPWRS.2015.2494082
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Grid connection of a DFIG for power generation changes the power system load flow and introduces dynamic interactions with the synchronous generators (SGs). A method is proposed in this paper for the separate examination of the impact of those two affecting factors, the change of load flow and dynamic interaction brought about by the DFIG, on the electromechanical oscillation modes of a power system. The method is developed on the establishment of a "closed-loop control system" type of state space model of the power system where the DFIG is treated as the feedback controller. The established model unambiguously indicates that the impact of the DFIG can be examined separately: (1) With the DFIG being modelled as a constant power injection into the system, the impact of the load flow change brought about by the DFIG on the oscillation modes is determined; (2) The impact of the dynamic interactions introduced by the DFIG is estimated by calculating the contribution of the damping torque from the DFIG with its full dynamics being considered. Thus a more detailed examination on and deeper insight into the impact of grid connection of the DFIGs on power system small-signal angular stability is obtained by using the proposed method.
引用
收藏
页码:3775 / 3784
页数:10
相关论文
共 26 条
[1]  
[Anonymous], MODERN POWER SYSTEMS
[2]   Comparison of 5th order and 3rd order machine models for doubly fed induction generator (DFIG) wind turbines [J].
Ekanayake, JB ;
Holdsworth, L ;
Jenkins, N .
ELECTRIC POWER SYSTEMS RESEARCH, 2003, 67 (03) :207-215
[3]   On the stability of power systems containing doubly fed induction generator-based generation [J].
Elkington, Katherine ;
Enazkins, Valerijs ;
Ghandhari, Mehrdad .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (09) :1477-1484
[4]  
Fan L., 2008, Power and Energy Society General Meeting-Conversion and Delivery of Electrical Energy in the 21st Century, P1
[5]   A third order model for the doubly-fed induction machine [J].
Feijóo, A ;
Cidrás, J ;
Carrillo, C .
ELECTRIC POWER SYSTEMS RESEARCH, 2000, 56 (02) :121-127
[6]  
Fernandez L. M., 2008, ELECTR POW SYST RES, V33, P1738
[7]   Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems [J].
Gautam, Durga ;
Vittal, Vijay ;
Harbour, Terry .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1426-1434
[9]   Small Signal Analysis of Power Systems With Wind and Energy Storage Units [J].
Jamehbozorg, Arash ;
Radman, Ghadir .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) :298-305
[10]   Modeling and control of DFIG-based variable-speed wind-turbine [J].
Ko, Hee-Sang ;
Yoon, Gi-Gab ;
Kyung, Nam-Ho ;
Hong, Won-Pyo .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) :1841-1849