Low-profile Visualized Intraluminal Support device (LVIS Jr) as a novel tool in the treatment of wide-necked intracranial aneurysms: initial experience in 32 cases

被引:65
作者
Behme, Daniel [1 ]
Weber, Anushe [1 ]
Kowoll, Annika [1 ]
Berlis, Ansgar [2 ]
Burke, Thomas H. [3 ]
Weber, Werner [1 ,4 ]
机构
[1] Knappschaftskrankenhaus, Klinikum Vest, Dept Radiol & Neuroradiol, Recklinghausen, Germany
[2] Klinikum Augsburg, Dept Radiol & Neuroradiol, Augsburg, Germany
[3] Microvent Terumo, Tustin, CA USA
[4] Ruhr Univ Bochum, Univ Med Ctr Knappschaftskrankenhaus Langendreer, Bochum, Germany
关键词
ASSISTED COIL EMBOLIZATION; EXPANDING NITINOL STENT; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; NEUROFORM STENT; ENTERPRISE STENT; MULTICENTER;
D O I
10.1136/neurintsurg-2014-011157
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background and purpose The focus of this study was to determine ease of deployment, safety and effectiveness of the LVIS Jr device. Methods A retrospective analysis was performed of 32 cases comprising 34 aneurysms in which the LVIS Jr device was used for stent-assisted coil embolization of intracranial aneurysms from February to October 2012, including all clinical and angiographic data as well as mid-term follow-up (1-12 months of treatment). Results The median age of the patients was 54 years (range 21-76) and 19 (59%) were women. The aneurysms were ruptured in 12/34 cases (35.3%); 26 (76.4%) were located within the anterior circulation and the remaining 8 (23.5%) were located in the posterior circulation. Eleven of the 34 aneurysms (32.3%) were treated with a Y-stent configuration. Immediate total occlusion was observed in 16/34 (47%), near total occlusion (90-95%) in 5/34 (14.7%) and a 'dog ear' or subtotal occlusion in 12/34 (35.2%). A single aneurysm was treated without coil embolization. Complications occurred in 5/34 cases (15%), including two cases of in-stent thrombosis. Conclusions Implantation of the LVIS Jr device as a support device for stent-assisted coil embolization seems to be safe and effective. The LVIS Jr device can also be implanted in a Y-stent configuration, offering a novel technique with a potentially lower risk of thromboembolic complications compared with other devices.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 43 条
  • [41] A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
    Matsuda, Yoshikazu
    Chung, Joonho
    Keigher, Kiffon
    Lopes, Demetrius
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (03) : 274 - 278
  • [42] Preliminary Experience with Stent-Assisted Coiling of Aneurysms Arising from Small (<2.5 mm) Cerebral Vessels Using The Low-Profile Visualized Intraluminal Support Device
    Wang, C. -C.
    Li, W.
    Feng, Z. -Z.
    Hong, B.
    Xu, Y.
    Liu, J. -M.
    Huang, Q. -H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (06) : 1163 - 1168
  • [43] Initial Experience with a New Self-Expanding Open-Cell Stent System with Antithrombotic Hydrophilic Polymer Coating (pEGASUS Stent) in the Treatment of Wide-Necked Intracranial Aneurysms
    Boxberg, Frederik
    Al-Tibi, Mohammad
    Schulz, Katharina
    Lanfermann, Heinrich
    Schlunz-Hendann, Martin
    Grieb, Dominik
    NEUROINTERVENTION, 2024, 19 (02) : 74 - 81