Low-profile Visualized Intraluminal Support device (LVIS Jr) as a novel tool in the treatment of wide-necked intracranial aneurysms: initial experience in 32 cases

被引:65
作者
Behme, Daniel [1 ]
Weber, Anushe [1 ]
Kowoll, Annika [1 ]
Berlis, Ansgar [2 ]
Burke, Thomas H. [3 ]
Weber, Werner [1 ,4 ]
机构
[1] Knappschaftskrankenhaus, Klinikum Vest, Dept Radiol & Neuroradiol, Recklinghausen, Germany
[2] Klinikum Augsburg, Dept Radiol & Neuroradiol, Augsburg, Germany
[3] Microvent Terumo, Tustin, CA USA
[4] Ruhr Univ Bochum, Univ Med Ctr Knappschaftskrankenhaus Langendreer, Bochum, Germany
关键词
ASSISTED COIL EMBOLIZATION; EXPANDING NITINOL STENT; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; NEUROFORM STENT; ENTERPRISE STENT; MULTICENTER;
D O I
10.1136/neurintsurg-2014-011157
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background and purpose The focus of this study was to determine ease of deployment, safety and effectiveness of the LVIS Jr device. Methods A retrospective analysis was performed of 32 cases comprising 34 aneurysms in which the LVIS Jr device was used for stent-assisted coil embolization of intracranial aneurysms from February to October 2012, including all clinical and angiographic data as well as mid-term follow-up (1-12 months of treatment). Results The median age of the patients was 54 years (range 21-76) and 19 (59%) were women. The aneurysms were ruptured in 12/34 cases (35.3%); 26 (76.4%) were located within the anterior circulation and the remaining 8 (23.5%) were located in the posterior circulation. Eleven of the 34 aneurysms (32.3%) were treated with a Y-stent configuration. Immediate total occlusion was observed in 16/34 (47%), near total occlusion (90-95%) in 5/34 (14.7%) and a 'dog ear' or subtotal occlusion in 12/34 (35.2%). A single aneurysm was treated without coil embolization. Complications occurred in 5/34 cases (15%), including two cases of in-stent thrombosis. Conclusions Implantation of the LVIS Jr device as a support device for stent-assisted coil embolization seems to be safe and effective. The LVIS Jr device can also be implanted in a Y-stent configuration, offering a novel technique with a potentially lower risk of thromboembolic complications compared with other devices.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 43 条
  • [21] Initial Experience with the Contour Device in the Treatment of Ruptured Intracranial Wide-necked Bifurcation Aneurysms: A Single-operator, Multicenter Study
    Dange, Nitin Narayan
    Roy, Joanna Mary
    NEUROLOGY INDIA, 2022, 70 (05) : 2059 - 2064
  • [22] Incomplete stent apposition of low-profile visualized intraluminal support stents in the treatment of cerebral aneurysms
    Zhang, Huan
    Gao, Xiaoping
    Liang, Hui
    Ren, Yi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (06) : 591 - 597
  • [23] Midterm results of T-stent-assisted coiling of wide-necked and complex intracranial bifurcation aneurysms using low-profile stents
    Aydin, Kubilay
    Sencer, Serra
    Barburoglu, Mehmet
    Berdikhojayev, Mynzhylky
    Aras, Yavuz
    Sencer, Altay
    Izgi, Nail
    JOURNAL OF NEUROSURGERY, 2017, 127 (06) : 1288 - 1296
  • [24] Results of Double Low-Profile Visualized Intraluminal Support Blue Stenting for the Treatment of Fusiform Cerebral Aneurysms
    Ban, Seung Pil
    Kwon, O-Ki
    Kim, Young Deok
    Lee, Yongjae
    WORLD NEUROSURGERY, 2023, 170 : E416 - E424
  • [25] Overlapped Stenting Combined with Coiling for Blood Blister-Like Aneurysms: Comparison of Low-Profile Visualized Intraluminal Support (LVIS) Stent and Non-LVIS Stent
    Zhu, Deyuan
    Fang, Yibin
    Yang, Pengfei
    Zhang, Ping
    Chen, Lei
    Xu, Yi
    Hong, Bo
    Huang, Qinghai
    Liu, Jian-Min
    WORLD NEUROSURGERY, 2017, 104 : 729 - 735
  • [26] Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms
    Yan, Zhiyuan
    Zheng, Kuang
    Xiong, Ye
    Lan, Fujun
    Wang, Yunhui
    Tan, Xianxi
    Zhong, Ming
    Li, Zequn
    WORLD NEUROSURGERY, 2019, 125 : E22 - E28
  • [27] Efficient simulation of a low-profile visualized intraluminal support device: A novel fast virtual stenting technique
    Zhang Q.
    Liu J.
    Zhang Y.
    Zhang Y.
    Tian Z.
    Li W.
    Chen J.
    Mo X.
    Cai Y.
    Paliwal N.
    Meng H.
    Wang Y.
    Wang S.
    Yang X.
    Chinese Neurosurgical Journal, 4 (1)
  • [28] Endovascular Treatment of Tiny Aneurysms With Low-Profile Visualized Intraluminal Support Devices Using a "Compressed" Stent Technique
    Zhou, Yangyang
    Peng, Qichen
    Wu, Xinzhi
    Zhang, Yisen
    Liu, Jian
    Yang, Xinjian
    Mu, Shiqing
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [29] Y-configuration stenting for coiling of wide-neck bifurcation aneurysms using Low-profile Visualized Intraluminal Support Junior
    Park, Keun Young
    Kim, Byung Moon
    Kim, Dong Joon
    Chung, Joonho
    Lee, Jae Whan
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) : 400 - 404
  • [30] Low-Profile Visualized Intraluminal Support Stent-Only Technique for Intracranial Aneurysms-A Report of 12 Cases with Midterm Follow-Up
    Liu, Qinglin
    Qi, Changjing
    Zhang, Yupeng
    Deng, Lin
    Li, Gang
    Su, Wandong
    WORLD NEUROSURGERY, 2019, 129 : E40 - E47