Control of DFIG under unsymmetrical voltage dip

被引:20
作者
Zhou, Y. [1 ]
Bauer, P. [1 ]
Ferreira, J. A. [1 ]
Pierik, J.
机构
[1] Delft Univ Technol, NL-2628 CD Delft, Netherlands
来源
2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6 | 2007年
关键词
D O I
10.1109/PESC.2007.4342113
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Today, doubly fed induction generator (DFIG) gains the dominant market power in the wind energy industry. It provides the benefits of variable speed operation cost-effectively, and can control its active and reactive power independently. Crowbar protection is often adopted to protect the rotor side voltage source converter (VSC) from transient over current during grid voltage dip. But under unsymmetrical voltage dip, the severe problems are not the transient over current, but the electric torque pulsation and DC voltage ripple in the back to back VSCs. This paper develops dynamic models in Matlab/Simulink, investigates the behavior of DFIG during an unsymmetrical voltage dip, and proposes new controllers in separated positive and negative sequence. Methods to separate positive and negative sequence components in real time are also developed, and their responses to unsymmetrical voltage dip are compared. Simulation results prove that the separated positive and negative sequence controller limit the torque pulsation and DC voltage ripple effectively.
引用
收藏
页码:933 / 938
页数:6
相关论文
共 12 条
[1]  
AKHMATOV, 2003, THESIS U DENMARK
[2]  
AKIRA N, 1996, IEEE T POWER DELIVER, V11
[3]  
[Anonymous], WIND POWER POWER SYS
[4]   Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances [J].
Holdsworth, L ;
Wu, XG ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) :343-352
[5]  
KIM H, 1997, P POW CONV C NAG
[6]  
Lyon W. V., 1954, TRANSIENT ANAL ALTER
[7]  
Marques G.D., 1998, P 24 ANN C IEEE IND
[8]  
MORREN J, 2005, WIND ENERGY, V8
[9]  
PETERSSON, 2005, THESIS CHALMERS U TE
[10]  
PIERIK J, 2004, ECNC04051 ECN TUD