Space charge compensation in air by counterion flow in 3D printed electrode structure

被引:3
作者
Marsh, Brett M. [1 ]
Rahman, Saquib [1 ]
Benkowski, Victoria M. [1 ]
Tichy, Shane [2 ]
Cooks, R. Graham [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Agilent Technol, 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA
关键词
Ion optics; Multiplexing; Ion sources; Rapid prototyping; Ambient ionization; MASS-SPECTROMETRY; ION-TRANSPORT; IONIZATION; NEUTRALIZATION; SIMULATION; BEAMS; SIMION; ARRAYS;
D O I
10.1016/j.ijms.2021.116637
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Electrospray ionization is commonly employed in modern mass spectrometry experiments for applications ranging from proteomics to environmental science and for fundamental studies of the chemical reactivity of ions. Despite the ubiquity of electrospray ionization, the total ion currents achieved using the technique remain relatively poor. While there are significant losses within the atmospheric pressure interface of the mass spectrometer (MS), many ions are lost due to space charge repulsion before ions and charged microdroplets enter the instrument. Space charge effects also limit the extent to which multiplexing of electrosprays can be used to increase ion currents. In this work, a flow of oppositely charged ions produced by atmospheric pressure chemical ionization (APCI) is employed to mitigate space charge effects in an analyte ion beam produced by nanoelectrospray ionization (nESI) as it is passed through an atmospheric pressure ion guide outside of a mass spectrometer. A decrease in the nESI beam width together with an increase in peak intensity is observed using an ion charge coupled detector in the presence of a counterflow of ions of the opposite charge. This result indicates that focusing occurs in the ion guide. Measurements of the space charge compensated ion beam using an Agilent Ultivo triple quadrupole mass spectrometer are correlated with changes in ion focusing, indicating that space charge compensation occurring before the ion beam enters the mass spectrometer can increase detected ion currents. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 48 条
[41]   Temporal distribution of ions in ambient pressure drift tubes with turns [J].
Schrader, Robert L. ;
Marsh, Brett M. ;
Cooks, R. Graham .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 456
[43]   Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler [J].
Thompson, JW ;
Eschelbach, JW ;
Wilburn, RT ;
Jorgenson, JW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (03) :312-323
[44]   Negative ion beam space charge compensation by residual gas [J].
Valerio-Lizarraga, Cristhian A. ;
Leon-Monzon, Ildefonso ;
Scrivens, Richard .
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2015, 18 (08)
[45]   SLA 3-D Printed Arrays of Miniaturized, Internally Fed, Polymer Electrospray Emitters [J].
Velasquez-Garcia, Luis Fernando .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2015, 24 (06) :2117-2127
[46]   Numerical Simulation of Ion Transport in a Nano-Electrospray Ion Source at Atmospheric Pressure [J].
Wang, Wei ;
Bajic, Steve ;
John, Benzi ;
Emerson, David R. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (03) :600-612
[47]   Simulation of Ion Motion at Atmospheric Pressure: Particle Tracing Versus Electrokinetic Flow [J].
Wissdorf, Walter ;
Pohler, Larissa ;
Klee, Sonja ;
Mueller, David ;
Benter, Thorsten .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (02) :397-406
[48]   Space-charge neutralization of heavy ion beams via electron injection [J].
Wu, LC ;
Miley, GH ;
Momota, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 544 (1-2) :533-537