Preparation, Characterization, and Corrosion Behavior of Calcium Phosphate Coating Electrodeposited on the Modified Nanoporous Surface of NiTi Alloy for Biomedical Applications

被引:27
作者
Sheykholeslami, Seyed Omid Reza [1 ]
Khalil-Allafi, Jafar [1 ]
Fathyunes, Leila [1 ]
机构
[1] Sahand Univ Technol, Fac Mat Engn, Res Ctr Adv Mat, Tabriz 5133511996, Iran
来源
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE | 2018年 / 49A卷 / 11期
关键词
CA-P COATINGS; ELECTROPHORETIC DEPOSITION; ELECTROCHEMICAL DEPOSITION; HYDROXYAPATITE COATINGS; COMPOSITE COATINGS; TITANIUM; BIOCOMPATIBILITY; DEGRADATION; ANODIZATION; BIOACTIVITY;
D O I
10.1007/s11661-018-4847-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the surface modification of the NiTi alloy was accomplished by anodizing in the ethylene glycol (EG)-based electrolyte and subsequent heat treatment at 823 K (550 degrees C) for 30 minutes. The field emission scanning electron microscopy images revealed that anodizing at 30 V led to the formation of a 3-D interconnected nanoporous TiO2 layer on the surface of NiTi. The existence of this oxide layer did not have a negative effect on the superelastic behavior of NiTi. In the next stage, this modified surface of samples was coated with calcium phosphate (Ca-P) ceramic using the pulsed electrodeposition method. Based on the results, anodizing of the NiTi substrate before electrodeposition promoted the quality of the applied coating. Moreover, electrodeposition at the higher current densities of 15 and 20 mA cm(-2) increased the possibility of the hydroxyapatite phase formation in the coating rather than the other less stable calcium phosphate phases. Additionally, both the TiO2 layer and the Ca-P coating significantly improved the corrosion resistance of the NiTi alloy and suppressed the release of Ni ions from its surface. At last, in comparison to the bare NiTi, the mechanical locks between the nanoporous structure of the modified sample and the Ca-P coating increased the bonding strength. (C) The Minerals, Metals & Materials Society and ASM International 2018
引用
收藏
页码:5878 / 5887
页数:10
相关论文
共 47 条
[41]   A novel hydroxyapatite composite reinforced with titanium nanotubes coated on Co-Cr-based alloy [J].
Shirdar, Mostafa Rezazadeh ;
Sudin, Izman ;
Taheri, Mohammad Mandi ;
Keyvanfar, Ali ;
Yusop, Mohd Zamri Mohd ;
Kadir, Mohammed Rafiq Abdul .
VACUUM, 2015, 122 :82-89
[42]   Formation of ZrO2 coating on the NiTi alloys for improving their surface properties [J].
Sui, J. H. ;
Cai, W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (02) :402-406
[43]   Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation [J].
Tan, L ;
Dodd, RA ;
Crone, WC .
BIOMATERIALS, 2003, 24 (22) :3931-3939
[44]   Stability of Ni in nitinol oxide surfaces [J].
Tian, He ;
Schryvers, Dominique ;
Liu, Di ;
Jiang, Qing ;
Van Humbeeck, Jan .
ACTA BIOMATERIALIA, 2011, 7 (02) :892-899
[45]   Electrolyte influence on the anodic synthesis of TiO2 nanotube arrays [J].
Vega, V. ;
Cerdeira, M. A. ;
Prida, V. M. ;
Alberts, D. ;
Bordel, N. ;
Pereiro, R. ;
Mera, F. ;
Garcia, S. ;
Hernandez-Velez, M. ;
Vazquez, M. .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2008, 354 (47-51) :5233-5235
[46]   In vitro degradation and mechanical integrity of Mg-Zn-Ca alloy coated with Ca-deficient hydroxyapatite by the pulse electrodeposition process [J].
Wang, H. X. ;
Guan, S. K. ;
Wang, X. ;
Ren, C. X. ;
Wang, L. G. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1743-1748
[47]   Anodization of NiTi alloy in an ethylene glycol electrolyte [J].
Yang, Zhendi ;
Wei, Xiaojin ;
Gao, Wei ;
Cao, Peng .
SURFACE & COATINGS TECHNOLOGY, 2014, 252 :142-147