Two types of hydroxyethyl-methacrylated dextran (dex-HEMA) hydrogels differing in crosslink density were compared for local tissue responses and degradation characteristics in mice and rats. Implants (1 mm thick, rat: 10 mm diameter, mouse: 6 mm diameter) varying in degree of HEMA substitution (DS5 and DS13, meaning 5 or 13 HEMA groups per 100 glucose units of dextran) were subcutaneously implanted and tissue responses were evaluated at week 2, 6, and 13 after implantation. In the rat after 2 weeks a slight fibrous capsule was formed composed of macrophages and fibroblasts sometimes accompanied by a minimal infiltrate. Small fragments, surrounded by macrophages and giant cells indicated hydrogel degradation. After 13 weeks DS5 implants were resorbed while parts of the DS13 implants were still present. In the mouse a moderate to strong capsule formation was present at 2 weeks accompanied by inflammatory cells (macrophages and polymorphonuclear granulocytes) and debris. Draining lymph node activation was observed. Skin ulceration was present irrespective of the type of implant. Clear differences in the tissue responses between the rat and mouse were noted, as well as between implants of different degree of substitution. Mice showed a more pronounced early inflammatory response compared with rats, whereas the degradation was more complete in rats than in mice. The differences in histology between the hydrogels disappeared over time at 13 weeks after implantation and similar responses were noted for both types of hydrogels. Both in mice and rats the DS5 hydrogels showed a faster degradation rate than the DS13 hydrogels. (c) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:538 / 545
页数:8
相关论文
共 29 条
[1]   Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices [J].
An, YH ;
Woolf, SK ;
Friedman, RJ .
BIOMATERIALS, 2000, 21 (24) :2635-2652
[2]   Spotlight on naturally absorbable osteofixation devices [J].
Ashammakhi, N ;
Suuronen, R ;
Tiainen, J ;
Törmälä, P ;
Waris, T .
JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (02) :247-259
[3]   Biocompatibility and degradation mechanisms of predegraded and non-predegraded poly(lactide) implants: An animal study [J].
Bergsma, JE ;
Rozema, FR ;
Bos, RRM ;
vanRozendaal, AWM ;
deJong, WH ;
Teppema, JS ;
Joziasse, CAP .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (12) :715-724
[4]  
Cadée JA, 2000, J BIOMED MATER RES, V50, P397
[5]   Release of recombinant human interleukin-2 from dextran-based hydrogels [J].
Cadée, JA ;
de Groot, CJ ;
Jiskoot, W ;
den Otter, W ;
Hennink, WE .
JOURNAL OF CONTROLLED RELEASE, 2002, 78 (1-3) :1-13
[6]  
Cadée JA, 2001, J BIOMED MATER RES, V56, P600, DOI 10.1002/1097-4636(20010915)56:4<600::AID-JBM1133>3.0.CO
[7]  
2-I
[8]   Effect of polymerization conditions on the network properties of dex-HEMA microspheres and macro-hydrogels [J].
Chung, JT ;
Vlugt-Wensink, KDF ;
Hennink, WE ;
Zhang, Z .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2005, 288 (01) :51-61
[9]   In vitro biocompatibility of biodegradable dextran-based hydrogels tested with human fibroblasts [J].
De Groot, CJ ;
Van Luyn, MJA ;
Van Dijk-Wolthuis, WNE ;
Cadée, JA ;
Plantinga, JA ;
Den Otter, W ;
Hennink, WE .
BIOMATERIALS, 2001, 22 (11) :1197-1203
[10]   Tissue response to partially in vitro predegraded poly-L-lactide implants [J].
De Jong, WH ;
Bergsma, JE ;
Robinson, JE ;
Bos, RRM .
BIOMATERIALS, 2005, 26 (14) :1781-1791