Velocity Measurement at Carotid Siphon: Quantitative Comparison of Phase Contrast MRI and Computational Fluid Dynamics

被引:0
作者
Zhang, Chi [1 ]
Yang, Jinfeng [1 ]
Ding, Ning [1 ]
Chang, Feiyan [2 ]
Xie, Sheng [2 ]
Li, Deyu [3 ]
Hou, Xiaoxu [4 ]
机构
[1] Beihang Univ, Beijing 100083, Peoples R China
[2] China Japan Friendship Hosp, Beijing 100029, Peoples R China
[3] Beihang Univ, State Key Lab Virtual Real Technol & Syst, Beijing 100083, Peoples R China
[4] Natl Inst Food & Drug Control, Beijing 102629, Peoples R China
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1 | 2019年 / 68卷 / 01期
关键词
Carotid siphon; Phase contrast magnetic resonance imaging; Computational fluid dynamics; Blood flow; Velocity field; BLOOD-FLOW; MAGNETIC-RESONANCE; VALIDATION; ARTERIES;
D O I
10.1007/978-981-10-9035-6_92
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Phase contrast magnetic resonance imaging (PC MRI) and the computational fluid dynamics (CFD) are two of the most important technologies in the investigation on the velocity field in blood vessels in vivo. In order to quantitatively compare the differences between the two methods, the blood flow velocity measurements based on PC MRI and patient-specific CFD were conducted at internal carotid artery from 9 healthy volunteers. The 3D velocity field calculated from PC MRI data were compared with CFD simulation in 5 planes covering the carotid siphon. Then the resistance index (RI), and errors in the magnitude and direction of velocity were calculated between the two methods. The results showed that the flow patterns of PC MRI and CFD were similar, and the velocity distribution and RI was in good agreement. But there were significant differences in the velocity magnitude near the posterior knee and vessel wall, while the directional error was larger at the center of the artery. These comparison between PC MRI and CFD may guide the development of CFD technology and improve its accuracy.
引用
收藏
页码:499 / 504
页数:6
相关论文
共 16 条
[1]  
Ali S. F., 2015, IRAN J RADIOL, V12
[2]   Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI [J].
Alperin, N ;
Vikingstad, EM ;
GomezAnson, B ;
Levin, DN .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :741-754
[3]   Simple Patient-Based Transmantle Pressure and Shear Estimate From Cine Phase-Contrast MRI in Cerebral Aqueduct [J].
Bardan, Gerald ;
Plouraboue, Franck ;
Zagzoule, Mokhtar ;
Baledent, Olivier .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (10) :2874-2883
[4]   Hemodynamics in normal cerebral arteries: qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics [J].
Cebral, Juan R. ;
Putman, Christopher M. ;
Alley, Marcus T. ;
Hope, Thomas ;
Bammer, Roland ;
Calamante, Fernando .
JOURNAL OF ENGINEERING MATHEMATICS, 2009, 64 (04) :367-378
[5]   MRI-Based Computational Fluid Dynamics for Diagnosis and Treatment Prediction: Clinical Validation Study in Patients With Coarctation of Aorta [J].
Goubergrits, Leonid ;
Riesenkampff, Eugenie ;
Yevtushenko, Pavlo ;
Schaller, Jens ;
Kertzscher, Ulrich ;
Hennemuth, Anja ;
Berger, Felix ;
Schubert, Stephan ;
Kuehne, Titus .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) :909-916
[6]   Comparison of Blood Flow Velocity Quantification by 4D Flow MR Imaging with Ultrasound at the Carotid Bifurcation [J].
Harloff, A. ;
Zech, T. ;
Wegent, F. ;
Strecker, C. ;
Weiller, C. ;
Markl, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (07) :1407-1413
[7]   3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T [J].
Harloff, A. ;
Albrecht, F. ;
Spreer, J. ;
Stalder, A. F. ;
Bock, J. ;
Frydrychowicz, A. ;
Schoellhorn, J. ;
Hetzel, A. ;
Schumacher, M. ;
Hennig, J. ;
Markl, M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) :65-74
[8]   IN-VIVO VALIDATION OF MAGNETIC-RESONANCE BLOOD-VOLUME FLOW MEASUREMENTS WITH LIMITED SPATIAL-RESOLUTION IN SMALL VESSELS [J].
HOFMAN, MBM ;
VISSER, FC ;
VANROSSUM, AC ;
VINK, GQM ;
SPRENGER, M ;
WESTERHOF, N .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (06) :778-784
[9]   Blood flow in the human ascending aorta: a combined MRI and CFD study [J].
Leuprecht, A ;
Kozerke, S ;
Boesiger, P ;
Perktold, K .
JOURNAL OF ENGINEERING MATHEMATICS, 2003, 47 (3-4) :387-404
[10]   Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation [J].
Lotz, J ;
Meier, C ;
Leppert, A ;
Galanski, M .
RADIOGRAPHICS, 2002, 22 (03) :651-671