Comparison of headspace-SPME-GC-MS and LC-MS for the detection and quantification of coumarin, vanillin, and ethyl vanillin in vanilla extract products

被引:80
作者
De Jager, Lowri S. [1 ]
Perfetti, Gracia A. [1 ]
Diachenko, Gregory W. [1 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, College Pk, MD 20785 USA
关键词
coumarin; vanilla; HS-SPME; GC-MS; LC-MS; headspace;
D O I
10.1016/j.foodchem.2007.09.070
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A headspace-solid phase micro-extraction (HS-SPME) GC-MS method has been developed for the determination of coumarin, vanillin and ethyl vanillin in vanilla products. Limits of detection ranged from 1.33 to 13.2 ng mL(-1). Accuracy and precision data for the method were measured and compared to those obtained using LC-ESI-MS. A survey of 24 commercially available vanilla products was completed using both techniques. No coumarin was detected in any of the samples. Examination of the GC-MS chromatograms revealed the presence of 18 other flavor related compounds in the samples. The method validation and sample analysis data using HS-SPME-GC-MS were comparable to those obtained using the LC-MS method. Because the two methods are conceptually different from one another, both methods would not be subject to the same interferences. This would allow them to be used as confirmatory methods for each other. Published by Elsevier Ltd.
引用
收藏
页码:1701 / 1709
页数:9
相关论文
共 18 条