Diode laser transscleral cyclophotocoagulation as primary surgical treatment for medically uncontrolled chronic angle closure glaucoma - Long-term clinical outcomes

被引:52
|
作者
Lai, JSM
Tham, CCY
Chan, JCH
Lam, DSC
机构
[1] United Christian Hosp, Dept Ophthalmol, Kowloon, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
[3] Hong Kong Eye Hosp, Kowloon, Hong Kong, Peoples R China
[4] Queen Mary Hosp, Hong Kong, Hong Kong, Peoples R China
关键词
chronic angle closure glaucoma; diode laser cyclophotocoagulation;
D O I
10.1097/01.ijg.0000151890.41239.c5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the long-term efficacy and safety of diode laser transscleral cyclophotocoagulation as primary surgical treatment of medically uncontrolled chronic angle closure glaucoma. Patients and Methods: Thirteen eyes of 13 Chinese patients with medically uncontrolled chronic angle closure glaucoma were treated with diode laser transscleral cyclophotocoagulation between February 2000 and May 2001, and followed up for over 18 months. Post-treatment anti-glaucoma medications were adjusted according to intraocular pressure. If intraocular pressure remained above 21 mm Hg despite medications for more than 4 weeks after cyclophotocoagulation, the procedure was repeated. Results: Mean follow-up +/- SD was 26.5 +/- 4.2 months. Two eyes required repeat cyclophotocoagulation at 6 weeks. Rate of relative success, defined as maintaining an intraocular pressure of 21 mm Hg or below with or without medications, was 92.3% (12 of 13 eyes). Rate of absolute success, defined as maintaining an intraocular pressure of 21 mm Hg or below without medications, was 0% (0 of 13 eyes). Mean SD intraocular pressure was reduced from 36.4 +/- 12.6 man Hg pre-operatively, to 18.7 +/- 12.2 mm Hg at final follow-up (P = 0.003, paired t test). The mean +/- SD number of intraocular pressure-lowering eye drops was reduced from 2.0 +/- 0.8 pre-operatively, to the lowest point of 0.5 +/- 0.8 at 12 months, and then gradually increased to 2.1 +/- 0.9 at final follow-up. The visual acuity improved after treatment in 2 of 13 eyes (15.4%), remained unchanged in 6 of 13 eyes (46.2%) and deteriorated in 5 of 13 eyes (38.5%). No major complications were encountered. Conclusion: Diode laser cyclophotocoagulation appeared to be an effective and safe primary surgical treatment of medically uncontrolled chronic angle closure glaucoma, with intraocular pressure lowering effect persisting for up to two years.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 11 条
  • [1] Diode laser transscleral cyclophotocoagulation in the treatment of chronic angle-closure glaucoma: A preliminary study
    Lai, JSM
    Tham, CCY
    Chan, JCH
    Lam, DSC
    JOURNAL OF GLAUCOMA, 2003, 12 (04) : 360 - 364
  • [2] Diode Laser Cyclophotocoagulation for Nanophthalmic Chronic Angle Closure Glaucoma
    Golan, Shani
    Kurtz, Shimon
    JOURNAL OF GLAUCOMA, 2015, 24 (02) : 127 - 129
  • [3] Outcomes of primary surgical treatment of medically recalcitrant post-keratoplasty glaucoma with transscleral cyclophotocoagulation
    Khodeiry, Mohamed
    Liu, Xiangxiang S.
    Sayed, Mohamed K.
    Lee, Richard K.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1658 - 1665
  • [4] Treatment Outcomes of Slow Coagulation Transscleral Cyclophotocoagulation In Pseudophakic Patients with Medically Uncontrolled Glaucoma
    Khodeiry, M. Mohamed
    Sheheitli, Huda
    Sayed, S. Mohamed
    Persad, J. Patrice
    Feuer, J. William
    Lee, K. Richard
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 229 : 90 - 99
  • [5] Long-Term Treatment Outcomes of Micropulse Transscleral Cyclophotocoagulation in Primary and Secondary Glaucoma: A 5-Year Analysis
    de Crom, Ronald M. P. C.
    Kujovic-Aleksov, Stefani
    Webers, Carroll A. B.
    Berendschot, Tos T. J. M.
    Beckers, Henny J. M.
    OPHTHALMOLOGY AND THERAPY, 2025, 14 (02) : 323 - 335
  • [6] Micropulse Transscleral Cyclophotocoagulation as Primary Surgical Treatment for Primary Open Angle Glaucoma in Taiwan during the COVID-19 Pandemic
    Chang, Hsiao-Ling
    Chao, Shih-Chun
    Lee, Ming-Tsung
    Lin, Hung-Yu
    HEALTHCARE, 2021, 9 (11)
  • [7] Long-term scanning laser ophthalmoscopy and perimetry in different severities of primary open and chronic angle closure glaucoma eyes
    Sihota, Ramanjit
    Rao, Aparna
    Srinivasan, Geetha
    Gupta, Viney
    Sharma, Ajay
    Dada, Tanuj
    Kalaiwani, M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (10) : 963 - 968
  • [8] Long-term outcomes of cyclophotocoagulation in refractory pediatric glaucoma: treatment response and success in 262 eyes
    Alhazzaa, Bader
    Alshahrani, Ali
    Aljefri, Sara
    Al Obaida, Ibrahim
    Al Owaifeer, Adi Mohammed
    Alotaibi, Nayef
    Elsayed, Maram E. A. Abdalla
    Ahmad, Khabir
    Malik, Rizwan
    JOURNAL OF AAPOS, 2024, 28 (01):
  • [9] A Comparative Study Between Diode Laser Cyclophotocoagulation and the Ahmed Glaucoma Valve Implant in Neovascular Glaucoma A Long-term Follow-up
    Yildirim, Nilgun
    Yalvac, Ilgaz Sagdic
    Sahin, Afsun
    Ozeer, Ahmet
    Bozca, Tarik
    JOURNAL OF GLAUCOMA, 2009, 18 (03) : 192 - 196
  • [10] Efficacy and safety of inferior 180° goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma
    Lai, JSM
    Tham, CCY
    Chua, JKH
    Lam, DSC
    JOURNAL OF GLAUCOMA, 2000, 9 (05) : 388 - 391