Solar Chimney for Natural Ventilation: A Review

被引:2
作者
Dhrubo, Abir Ahsan [1 ]
Alam, Chowdhury Sadid [1 ]
Rahman, Md. Mustafizur [1 ]
Islam, A. K. M. Sadrul [1 ]
机构
[1] IUT, Dept Mech & Chem Engn, Gazipur 1704, Bangladesh
来源
7TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING (ICTE) | 2017年 / 1851卷
关键词
AIR HEAT-EXCHANGERS; AMERICAN CONVENTIONAL CRUDES; NUMERICAL-SIMULATION; COOLING SYSTEM; PIPE SYSTEMS; EAHE SYSTEMS; EARTH; BUILDINGS; PERFORMANCE; SOIL;
D O I
10.1063/1.4984637
中图分类号
O59 [应用物理学];
学科分类号
摘要
In the 21st century the talk of the time has been proper use of renewable energy sources due to the continuous depletion of non-renewable energy sources and global warming as a result of combustion of fossil fuels. The energy situation in the 3rd world countries is even worse. The continuous industrial development in the 1st world countries is hugely responsible for global temperature increase and greenhouse gas (GHG) emissions which badly affect the countries like Bangladesh. As of April 2016, the electricity generation capacity of Bangladesh was 12,399 MW to which only 60% of the total population have access to. The shortage of electricity during the summer season makes life very difficult. Cooling of buildings requires a large quantity of energy in the summer. An alternative cooling system can reduce the dependency on electricity. This paper specially deals with a passive cooling system that reduces pressure on the electricity supply and focuses on renewable energy sources. Here a different process engineering has been discussed which incorporates Earth-to-Air Heat Exchangers with solar collector enhanced solar chimney system. In this study natural ventilation of buildings, using solar chimney system is reviewed extensively. Experimentally it has already been observed that sufficient temperature drop takes place 2-3 m within the undisturbed ground, which can work as a heat sink for ambient air if passed through and can lead to attaining comfort zone at a confined location. During peak hours of summer this kind of system may work as a very efficient cooling system and reduces extra load on electricity supply.
引用
收藏
页数:8
相关论文
共 34 条
[1]   The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate [J].
Al-Ajmi, F ;
Loveday, DL ;
Hanby, VI .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :235-244
[2]   A STUDY OF SOLAR CHIMNEY ASSISTED WIND TOWER SYSTEM FOR NATURAL VENTILATION IN BUILDINGS [J].
BANSAL, NK ;
MATHUR, R ;
BHANDARI, MS .
BUILDING AND ENVIRONMENT, 1994, 29 (04) :495-500
[3]   Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: A review [J].
Bisoniya, Trilok Singh ;
Kumar, Anil ;
Baredar, Prashant .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 :238-246
[4]  
Bisoniya TrilokSingh, REV ARTICLE
[5]   Numerical simulation, technical and economic evaluation of air-to-earth heat exchanger coupled to a building [J].
Bojic, M ;
Trifunovic, N ;
Papadakis, G ;
Kyritsis, S .
ENERGY, 1997, 22 (12) :1151-1158
[6]   Passive heating and cooling strategies in an approaches of retrofit in Rome [J].
Calderaro, Valerio ;
Agnoli, Stefano .
ENERGY AND BUILDINGS, 2007, 39 (08) :875-885
[7]   Utilization of cool ceiling with roof solar chimney in Thailand: The experimental and numerical analysis [J].
Chungloo, Sudaporn ;
Limmeechokchai, Bundit .
RENEWABLE ENERGY, 2009, 34 (03) :623-633
[8]   Enhancement of natural ventilation in a solar house with a solar chimney and a solid adsorption cooling cavity [J].
Dai, YJ ;
Sumathy, K ;
Wang, RZ ;
Li, YG .
SOLAR ENERGY, 2003, 74 (01) :65-75
[9]   Theoretical and practical evaluation of an earth-tube (E-tube) ventilation system [J].
Darkwa, J. ;
Kokogiannakis, G. ;
Magadzire, C. L. ;
Yuan, K. .
ENERGY AND BUILDINGS, 2011, 43 (2-3) :728-736
[10]   Compact buried pipes system analysis for indoor air conditioning [J].
Freire, Alexandre de Jesus ;
Coelho Alexandre, Jose Luis ;
Silva, Valter Bruno ;
Couto, Nuno Dinis ;
Rouboa, Abel .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :1124-1134