Modified minimal model using a single-step fitting process for the intravenous glucose tolerance test in Type 2 diabetes and healthy humans

被引:6
作者
Zheng, YZ
Zhao, M
机构
[1] Vanderbilt Univ, Div Nephrol, Nashville, TN 37232 USA
[2] BIOSEP, Nashville, TN 37212 USA
关键词
intravenous glucose tolerance test; dynamical integrated glucose-insulin system; modified minimal model;
D O I
10.1016/j.cmpb.2005.03.007
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The classical minimal model with single compartment was modified by the assumption that the insulin decay rate is not always a first-order process, and a mathematical function for describing the insulin infusion rate is introduced. The modified model was used to study four sets of published data including healthy humans and Type 2 diabetes with different types of insulin infusion rates. The single-step fitting process took the glucose-insulin system as a dynamic integrated physiological system and generated the real optimized model parameters from the experimental data using the modified model. It also avoided the errors from the interpolation or extrapolation for taking measured insulin points as inputs, which were mostly employed in publications when using the single or multi-compartments minimal model. The averaged R-2 value between measured and calculated plasma concentrations for these four cases is 0.977, which indicates excellent agreement. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 10 条
[1]  
ANDREA C, 1999, AM J PHYSIOL, V276, pE1171
[2]   QUANTITATIVE ESTIMATION OF INSULIN SENSITIVITY [J].
BERGMAN, RN ;
IDER, YZ ;
BOWDEN, CR ;
COBELLI, C .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (06) :E667-E677
[3]  
Cobelli C, 1999, AM J PHYSIOL-ENDOC M, V277, pE481
[4]  
GAETANO AD, 2000, J MATH BIOL, V40, P136
[5]   Insulin sensitivity and glucose effectiveness from three minimal models: effects of energy restriction and body fat in adult male rhesus monkeys [J].
Gresl, TA ;
Colman, RJ ;
Havighurst, TC ;
Byerley, LO ;
Allison, DB ;
Schoeller, DA ;
Kemnitz, JW .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2003, 285 (06) :R1340-R1354
[6]   Comparison of insulin sensitivity and glucose effectiveness determined by the one- and two-compartment-labeled minimal model in late prepubertal children and early adolescents [J].
Hoffman, RP ;
Vicini, P ;
Cobelli, C .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2002, 51 (12) :1582-1586
[7]   Assessment of insulin sensitivity and secretion with the labelled intravenous glucose tolerance test: improved modelling analysis [J].
Mari, A .
DIABETOLOGIA, 1998, 41 (09) :1029-1039
[8]   MINMOD - A COMPUTER-PROGRAM TO CALCULATE INSULIN SENSITIVITY AND PANCREATIC RESPONSIVITY FROM THE FREQUENTLY SAMPLED INTRAVENOUS GLUCOSE-TOLERANCE TEST [J].
PACINI, G ;
BERGMAN, RN .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1986, 23 (02) :113-122
[9]   QUANTITATIVE ESTIMATION OF BETA-CELL SENSITIVITY TO GLUCOSE IN THE INTACT ORGANISM - A MINIMAL MODEL OF INSULIN KINETICS IN THE DOG [J].
TOFFOLO, G ;
BERGMAN, RN ;
FINEGOOD, DT ;
BOWDEN, CR ;
COBELLI, C .
DIABETES, 1980, 29 (12) :979-990
[10]   Physiologic modeling of the intravenous glucose tolerance test in type 2 diabetes: A new approach to the insulin compartment [J].
Ward, GM ;
Walters, JM ;
Barton, J ;
Alford, FP ;
Boston, RC .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2001, 50 (05) :512-519