Model-based crosstalk compensation for simultaneous 99mTc/123I dual-isotope brain SPECT imaging

被引:29
作者
Du, Yong [1 ]
Tsui, Benjamin M. W. [1 ]
Frey, Eric C. [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Radiol, Div Med Imaging Phys, Baltimore, MD 21287 USA
关键词
brain SPECT imaging; dual isotope; crosstalk compensation;
D O I
10.1118/1.2768863
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, we developed a model-based method to estimate and compensate for the crosstalk contamination in simultaneous 123 1 and Tc-99mm dual isotope brain single photo emission computed tomography imaging. The model-based crosstalk compensation (MBCC) includes detailed modeling of photon interactions inside both the object and the detector system. In the method, scatter in the object is modeled using the effective source scatter estimation technique, including contributions from all the photon emissions. The effects of the collimator-detector response, including the penetration and scatter components due to high-energy 1231 photons, are modeled using precalculated tables of Monte Carlo simulated point-source response functions obtained from sources in air at various distances from the face of the collimator. The model-based crosstalk estimation method was combined with iterative reconstruction based compensation to reduce contamination due to crosstalk. The MBCC method was evaluated using Monte Carlo simulated and physical phantom experimentally acquired simultaneous dual-isotope data. Results showed that, for both experimental and simulation studies, the model-based method provided crosstalk estimates that were in good agreement with the true crosstalk. Compensation using MBCC improved image contrast and removed the artifacts for both Monte Carlo simulated and experimentally acquired data. The results were in good agreement with images acquired without any. crosstalk contamination. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3530 / 3543
页数:14
相关论文
共 39 条
[1]  
Acton PD, 1999, BEHAV NEUROL, V12, P11
[2]  
Acton PD, 1999, J NUCL MED, V40, p145P
[3]  
Briesmeister J.F., 1997, LA12625M
[4]  
Chung YA, 2002, J NUCL MED, V43, p201P
[5]   Simultaneous 99mTc/201Tl dual-isotope SPET with Monte Carlo-based down-scatter correction [J].
de Jong, HWAM ;
Beekman, FJ ;
Viergever, MA ;
van Rijk, PP .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (08) :1063-1071
[6]  
DEVOUS MD, 1992, J NUCL MED, V33, P2030
[7]  
Dresel S, 1998, J NUCL MED, V39, p7P
[8]   Model-based compensation for quantitative 123I brain SPECT imaging [J].
Du, Y ;
Tsui, BMW ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05) :1269-1282
[9]   Optimization of acquisition energy windows in simultaneous 99mTc/123I brain SPECT [J].
Du, Y ;
Frey, EC ;
Wang, WT ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1556-1561
[10]   Combination of MCNP and SimSET for Monte Carlo simulation of SPECT with medium- and high-energy photons [J].
Du, Y ;
Frey, EC ;
Wang, WT ;
Tocharoenchai, C ;
Baird, WH ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :668-674